STEP
|
INSPECTION
|
ACTION
|
1
|
Remove the ROOM 15 A fuse and METER 7.5 A fuse.
Are the fuses normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect related wiring harness, then replace the fuse.
|
2
|
Measure the battery voltage.
Is the voltage between 8.5-16 V?
|
Yes
|
Go to the next step.
|
No
|
Battery malfunction
Inspect the charge/discharge system.
|
3
|
Measure the voltage between PJB terminal P and base unit terminal 1B.
Is the voltage between 8.5-16 V?
|
Yes
|
Go to the next step.
|
No
|
Inspect fuses and related wiring harness between the battery and PJB.
• If there is malfunction, repair or replace the applicable part.
|
4
|
Install the ROOM 15 A fuse and METER 7.5 A fuse.
Turn the ignition switch to the ACC position.
Measure the voltage at the base unit terminals 1B and 1R.
Is the voltage between 8.5-16 V?
|
Yes
|
Go to the next step.
|
No
|
Repair the wiring harness between the PJB and base unit.
|
5
|
Turn the ignition switch to the ACC or ON position and hold for 30 s or more.
Is DTC 09: Er20 displayed?
|
Yes
|
Replace the base unit.
|
No
|
DTC troubleshooting completed.
|