LIFTGATE LOCK ACTUATOR INSPECTION
id091400804400
1. Apply battery positive voltage and connect ground to the corresponding liftgate lock actuator terminals, and inspect the liftgate lock actuator operation.
-
• If not as specified, replace the liftgate latch and lock actuator.
Lock actuator operation
|
Connection
|
B+
|
GND
|
Lock
|
A
|
B
|
Unlock
|
B
|