LIFTGATE LOCK ACTUATOR INSPECTION


id091400804400

1. Apply battery positive voltage and connect ground to the corresponding liftgate lock actuator terminals, and inspect the liftgate lock actuator operation.

• If not as specified, replace the liftgate latch and lock actuator.

Lock actuator operation

Connection

B+

GND

Lock
A
B
Unlock
B
A