VARIABLE AIR DUCT (VAD) SOLENOID VALVE INSPECTION [MZR 2.5]


id0113d08037d3


Airflow Inspection

1.  Disconnect the negative battery cable.

2.  Remove the VAD solenoid valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR 1.8, MZR 2.0, MZR 2.5].)

3.  Inspect airflow between the ports under the following conditions.

am6zzw00005171
am6zzw00005172

•  If not as specified, replace the VAD solenoid valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR 1.8, MZR 2.0, MZR 2.5].)