VARIABLE SWIRL SOLENOID VALVE CONSTRUCTION/OPERATION [MZR 2.0 DISI]


id0113d4729200


Construction

•  Mainly composed of the coil, spring, and plunger.

Operation

Energized
•  The coil magnetizes, pulling the plunger. The passage between A and B ports opens due to the plunger being pulled, and intake manifold vacuum is applied to the variable swirl shutter valve actuator.
Not energized
•  The intake manifold vacuum passage is blocked, and the passage between ports B and C opens, depressurizing the variable swirl shutter valve actuator.
am6zzn00001716