FUEL PUMP UNIT INSPECTION [MZR 1.8, MZR 2.0, MZR 2.5]
id0114d3801100
Continuity Inspection
1. Disconnect the negative battery cable.
2. Disconnect the fuel pump unit connector.
3. Inspect for continuity between fuel pump unit terminals B—D.
am6zzw00005185
|