MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR REMOVAL/INSTALLATION [MZR 2.0 DISI]
id0140j3804300
1. Disconnect the negative battery cable.
2. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [MZR 2.0 DISI].)
3. Disconnect the MAP sensor connector.
4. Remove the MAP sensor.
am6zzw00007342
|
5. Install in the reverse order of removal.