DTC P0615:12 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]
id09021c405900
DESCRIPTION
|
Short to power supply in starter relay circuit
|
DETECTION CONDITION
|
• Keyless control module detects that the voltage of starter relay circuit is higher than the specification under the following conditions:
|
POSSIBLE CAUSE
|
• Starter relay malfunction
• Keyless control module connector or terminals malfunction
• Short to power supply in wiring harness between the following terminals:
MZR 1.8, MZR 2.0, MZR 2.5, MZR 2.0 DISI
MZR-CD 2.2
• Keyless control module malfunction
|
![]() |
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT STARTER RELAY
• Switch the ignition to off.
• Disconnect the negative battery cable.
• Remove the starter relay.
• Inspect the starter relay.
(See RELAY INSPECTION.)
• Is there any malfunction?
|
Yes
|
Replace the starter relay, then go to Step 5.
|
No
|
Install the starter relay, then go to the next step.
|
||
2
|
INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
• Disconnect the keyless control module connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT STARTER RELAY CIRCUIT FOR SHORT TO POWER SUPPLY
• Reconnect the negative battery cable.
• Measure the voltage at the following terminals (wiring harness-side):
• Is there any voltage?
|
Yes
|
Repair or replace the wiring harness for a possible short to power supply, then go to Step 5.
|
No
|
Go to the next step.
|
||
4
|
INSPECT KEYLESS CONTROL MODULE
• Switch the ignition to off.
• Disconnect the negative battery cable.
• Make sure to reconnect the disconnected connectors.
• Remove the starter relay.
• Reconnect the negative battery cable.
• Measure the voltage at the keyless control module terminal 4B (wiring harness-side) with the clutch not depressed.
• Is the voltage more than 6 V?
|
Yes
|
Replace the keyless control module, then go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect the disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC from the keyless control module using the M-MDS.
• Switch the ignition to off.
• Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Repeat the inspection from Step 1.
If the malfunction recurs, replace the keyless control module, then go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|