ON-BOARD DIAGNOSTIC SYSTEM [DOSING CONTROL UNIT (SKYACTIV-D 2.2)]
id0102k1078000
Outline
Function
Malfunction detection function
DTC table
DTC No. |
Check engine light |
Master warning indication/master warning light |
Charging system warning indication/charging system warning light |
Engine oil warning indication/engine oil warning light |
Engine oil level warning indication/Engine oil level warning light |
Wrench warning indication |
Diesel particulate filter indication/Diesel particulate filter indicator light |
Glow Indicator Light |
Selective catalytic reduction (SCR) warning light |
Condition |
Fail-safe function |
Drive cycle |
Monitor item |
Self test type*1 |
Memory function |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P0137:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (oxygen concentration) circuit low input
|
—
|
1
|
NOx sensor No.1
|
C
|
×
|
P0138:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (oxygen concentration) circuit high input
|
—
|
1
|
NOx sensor No.1
|
C
|
×
|
P2002:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor efficiency below threshold
|
—
|
2
|
PM sensor
|
C
|
×
|
P202E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
Urea injector circuit range/performance problem
|
×
|
1 or 2
|
CCM
|
C
|
×
|
P203A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor circuit problem
|
—
|
1
|
CCM
|
C
|
×
|
P203B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor malfunction
|
×
|
1
|
CCM
|
C
|
×
|
P203C:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor circuit low input
|
×
|
1
|
CCM
|
C, O
|
×
|
P203D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor circuit high input
|
×
|
1
|
CCM
|
C, O
|
×
|
P203E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor malfunction
|
—
|
2
|
CCM
|
C
|
×
|
P2047:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea injector control circuit problem
|
×
|
1
|
CCM
|
C
|
×
|
P2048:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea injector circuit low input
|
×
|
1
|
CCM
|
C, O
|
×
|
P2049:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea injector circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
P204F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump performance problem problem
|
×
|
1
|
CCM
|
C
|
×
|
P205A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea temperature sensor circuit problem
|
×
|
1
|
CCM
|
C
|
×
|
P205B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank temperature sensor circuit range/performance
|
×
|
1
|
CCM
|
C
|
×
|
P208A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump control circuit malfunction
|
×
|
1
|
CCM
|
C
|
×
|
P208B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
Urea pump (pumping side) range/performance problem
|
×
|
1 or 2
|
CCM
|
C
|
×
|
P208C:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump control circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
P208D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump control circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
P20B9:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control circuit malfunction
|
×
|
1
|
CCM
|
C
|
×
|
P20BB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
P20BC:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
P20BD:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater circuit problem
|
×
|
1
|
CCM
|
C, O
|
×
|
P20BF:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater control circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
P20C0:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater circuit high input
|
×
|
1
|
CCM
|
C, O
|
×
|
P20E8:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump pressure too low
|
×
|
1
|
SCR converter
|
C
|
×
|
P20E9:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump pressure too high
|
×
|
1
|
SCR converter
|
C
|
×
|
P20EA:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
SCR relay No.1 malfunction
|
—
|
1
|
CCM
|
C
|
×
|
P20EB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
SCR relay No.1 malfunction (stuck closed)
|
—
|
1
|
CCM
|
C
|
×
|
P20EE:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
SCR converter efficiency below threshold
|
×
|
1
|
CCM
|
C
|
×
|
P20FA:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Open circuit in urea pump circuit
|
×
|
1
|
CCM
|
C, O
|
×
|
P20FB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump (siphoning side) range/performance problem
|
—
|
2
|
CCM
|
C
|
×
|
P20FC:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
P20FD:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea pump circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
P20FF:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Dosing control unit malfunction
|
—
|
1
|
CCM
|
C
|
×
|
P214F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control malfunction
|
×
|
1
|
CCM
|
C
|
×
|
P21C5:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor: Detection performance malfunction
|
×
|
2
|
CCM
|
C
|
×
|
P21CB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Dosing control unit power supply voltage low input
|
—
|
1
|
CCM
|
C
|
×
|
P21CC:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Dosing control unit power supply voltage high input
|
—
|
1
|
CCM
|
C
|
×
|
P21DD:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control malfunction
|
×
|
1
|
CCM
|
C
|
×
|
P2200:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 control circuit range/performance problem
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
P2201:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx sensor No.1 system: Nox concentration malfunction
|
—
|
2
|
Nox sensor No.1
|
C
|
×
|
P2202:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (NOx oxygen concentration) circuit low input
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
P2203:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (NOx oxygen concentration) circuit high input
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
P2204:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Continuous monitoring of NOx sensor No.1 signal validity
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
P2205:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 heater control circuit range/performance problem
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
P220A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1: power supply voltage malfunction
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
P220B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2: power supply voltage malfunction
|
×
|
1
|
NOx sensor No.2
|
C
|
×
|
P220E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx Sensor No.1 heater: performance problem
|
×
|
1
|
Nox sensor No.1
|
C
|
×
|
P220F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx Sensor No.2 heater: performance problem
|
—
|
2
|
Nox sensor No.2
|
C
|
×
|
P221C:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater control circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
P221D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
P2270:00
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor (oxygen concentration): lean
|
×
|
2
|
NOx sensor
|
C
|
×
|
P2274:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor (oxygen concentration): lean
|
×
|
2
|
NOx sensor
|
C
|
×
|
P229E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2 control circuit range/performance problem
|
×
|
1
|
NOx sensor No.2
|
C
|
×
|
P229F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx sensor No.2 system: Nox concentration malfunction
|
—
|
2
|
Nox sensor No.2
|
C
|
×
|
P22A0:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor circuit low input
|
—
|
1
|
NOx sensor No.2
|
C
|
×
|
P22A1:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2 circuit high input
|
×
|
1
|
NOx sensor No.2
|
C
|
×
|
P22A2:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
Continuous monitoring of NOx sensor No.2 signal validity
|
×
|
2
|
Nox sensor No.2
|
C
|
×
|
P22A3:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2 heater control circuit range/performance problem
|
×
|
1
|
NOx sensor No.2
|
C
|
×
|
P24AE:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor control circuit range/performance problem
|
—
|
1*2, 2*3
|
PM sensor
|
C
|
×
|
P24AF:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor circuit range/performance
|
—
|
2
|
PM sensor
|
C
|
×
|
P24B1:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor circuit high input
|
—
|
1*2, 2*3
|
PM sensor
|
C
|
×
|
P24B3:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal heater circuit current low input
|
—
|
1
|
PM sensor
|
C
|
×
|
P24B6:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal heater circuit current high input
|
—
|
1
|
PM sensor
|
C
|
×
|
P24B7:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor heater resistance malfunction
|
—
|
2
|
PM sensor
|
C
|
×
|
P24C6:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal temperature sensor malfunction
|
—
|
1
|
CCM
|
C
|
×
|
P24C7:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor temperature circuit range/performance
|
—
|
2
|
PM sensor
|
C
|
×
|
P24D0:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal supply voltage malfunction
|
—
|
1
|
PM sensor
|
C
|
×
|
P24DA:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor system: Protection tube error
|
—
|
2
|
PM sensor
|
C
|
×
|
U0073:00
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN system communication error (HS CAN)
|
×
|
1
|
other
|
C, O
|
×
|
U0100:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication: communication error to PCM
|
×
|
1
|
CCM
|
C, O
|
×
|
U029D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication system: NOx sensor No.1 information communication error with dosing control unit
|
×
|
1
|
CCM
|
C, O
|
×
|
U029E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication system: NOx sensor No.2 information communication error with dosing control unit
|
×
|
1
|
CCM
|
C, O
|
×
|
U02A2:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
SENT communication system: urea quality sensor information communication error with dosing control unit
|
×
|
1
|
CCM
|
C, O
|
×
|
U02A3:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication system: PM sensor information communication error with dosing control unit
|
—
|
1
|
CCM
|
C, O
|
×
|
Status byte for DTC
ac5wzn00004012
|
Detection condition for the applicable DTC
DTC No. |
Condition |
Detection condition |
---|---|---|
P0137:00
|
NOx sensor No.1 (oxygen concentration) circuit low input
|
• The oxygen concentration output by NOx sensor No.1 is less than the specified value for a continuous 0.5 s.
|
P0138:00
|
NOx sensor No.1 (oxygen concentration) circuit high input
|
• The oxygen concentration output by NOx sensor No.1 exceeds the specification for a continuous 0.5 s.
|
P2002:00
|
PM sensor efficiency below threshold
|
• The internal circuit voltage or current of the PM sensor is not within the threshold value.
|
P202E:00
|
Urea injector circuit range/performance problem
|
• If any of the following conditions is met under condition A or condition B: 2 s in the control circuit of the urea injector.
Condition A:
• When the following condition is met, the dosing control unit detects the urea injector circuit current 0.2 A or less for 1 min:
MONITORING CONDITIONS
Condition B:
• When the following condition is met, the dosing control unit detects the urea injector coil temperature than more 33.5 °C {92.3 °F} for 0.1 s:
MONITORING CONDITIONS
|
P203A:00
|
Urea level sensor circuit problem
|
• When any of the following conditions is met:
|
P203B:00
|
Urea level sensor malfunction
|
• With all of the following conditions met, the signal cycle sent from the urea level sensor to the dosing control unit is not within the specified range for a continuous 4 s.
MONITORING CONDITIONS
|
P203C:00
|
Urea level sensor circuit low input
|
• The dosing control unit detects that the output duty signal circuit voltage of the urea level sensor is more than 1.18 V for 2 s.
MONITORING CONDITIONS
|
P203D:00
|
Urea level sensor circuit high input
|
• The dosing control unit detects that the output duty signal circuit voltage of the urea level sensor exceeds 2.05 V for 2 s.
MONITORING CONDITIONS
|
P203E:00
|
Urea level sensor malfunction
|
• With all of the following conditions met, the dosing control unit receives a reception signal from the urea level sensor only less than 3 times while the vehicle is being driven 5 km {3 mile} or more.
MONITORING CONDITIONS
|
P2047:00
|
Urea injector control circuit problem
|
• With the following conditions met, the difference between the high pressure side and the low pressure side of the urea injector voltage is more than 1 V for a continuous 2 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Battery voltage: 8—6 V
|
P2048:00
|
Urea injector circuit low input
|
• The dosing control unit detects the following conditions for 2 s in the control circuit of the urea injector.
MONITORING CONDITIONS
|
P2049:00
|
Urea injector circuit high input
|
• The dosing control unit detects the following conditions for 2 s in the control circuit of the urea injector.
MONITORING CONDITIONS
|
P204F:00
|
Urea pump performance problem problem
|
• With the following conditions met, the urea pump pressure does not increase for a continuous 0.2 s or more.
MONITORING CONDITIONS
• Engine speed: 300 rpm or more
• Exhaust gas temperature sensor No.5: 169.96 °C {337.93 °F} or more
• Urea pump pressure: less than 620 kPa {6.32 kgf/cm2, 89.9 psi}
• The following DTCs are not detected:
• Ignition switched ON (engine on)
• Battery voltage: 10 V or more
|
P205A:00
|
Urea temperature sensor circuit problem
|
• If any of the following conditions is met under condition A or condition B:
Condition A:
• The dosing control unit detects that the AdBlue® temperature in the urea tank is less than −40 °C {−40 °F} three times continuously.
MONITORING CONDITIONS
Condition B:
• The dosing control unit detects that the AdBlue® temperature in the urea tank exceeds 80 °C {176 °F} three times continuously.
MONITORING CONDITIONS
|
P205B:00
|
Urea tank temperature sensor circuit range/performance
|
• With the following conditions met, the difference between the urea temperature sensor and the engine oil temperature sensor is higher than 19.56 °C {67.21 °F} or the difference between the urea temperature sensor and the engine oil temperature is lower than –29.3 °C {–20.8 °F} for a continuous 4 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Period vehicle being left: 6 h or more
• Exhaust gas temperature sensor No.5: 169.96 °C {337.93 °F} or more
• ECT sensor No.1: 14.96 °C {58.93 °F} or more
• Ambient air temperature: 14.96 °C {58.93 °F} or more
• AdBlue® amount: 23.5 %
• The following DTCs are not detected:
• Battery voltage: 10 V or more
|
P208A:00
|
Urea pump control circuit malfunction
|
• With the following conditions met, the urea pump output voltage is between 2.6 V and 3.4 V for a continuous 2 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Battery voltage: 10—16 V
|
P208B:00
|
Urea pump (pumping side) range/performance problem
|
• When the following conditions are met, the dosing control unit detects the urea pump (pumping side) is not normally operating:
Condition A:
• With the following conditions met, the number of armature operation malfunction detections in the urea pump exceeds the specified value for a continuous 2.5 s.
MONITORING CONDITIONS
Condition B:
• With the following conditions met, the urea pump pressure calculation value is 140 kPa {1.43 kgf/cm2, 20.3psi} higher or more than the barometric pressure for a continuous 0.1 s.
MONITORING CONDITIONS
Condition C:
• With all of the following conditions met, the deviation of the AdBlue® current calculated by the dosing control unit based on the urea pump control current and urea temperature sensor is 14 % or more for a continuous 5.1 s.
MONITORING CONDITIONS
|
P208C:00
|
Urea pump control circuit low input
|
• With the following conditions met, the urea pump output voltage is between 1.6 V and 2.4 V or the urea pump supply voltage is between 0 V and 0.35 V for a continuous 2 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Battery voltage: 8—16 V
|
P208D:00
|
Urea pump control circuit high input
|
• With the following conditions met, the urea pump output current is between 1.5 A and 3.0 A or the urea pump supply voltage is between 1.65 V and 1.94 V for a continuous 1 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Battery voltage: 8—16 V
|
P20B9:00
|
Urea tank heater control circuit malfunction
|
• With the following conditions met, the voltage at the urea tank heater is between 1.1 V and 1.31 V for a continuous 2 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Urea tank heater is not operated.
• Battery voltage: 8—16 V
|
P20BB:00
|
Urea tank heater circuit low input
|
• If any of the following conditions is met under condition A or condition B:
Condition A:
• The dosing control unit detects that the voltage of the urea tank heater control circuit is 0—0.35 V for 2 s.
MONITORING CONDITIONS
Condition B:
• The dosing control unit detects that the voltage of the urea tank heater control circuit is exceeds 3.29 V for 2 s.
MONITORING CONDITIONS
|
P20BC:00
|
Urea tank heater control circuit high input
|
• With the following conditions met, the voltage at the urea tank heater is between 1.1 V and 1.31 V for a continuous 2 s.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• Urea tank heater is not operated.
• Battery voltage: 8—16 V
|
P20BD:00
|
Urea hose heater circuit problem
|
• With all of the following conditions met, the urea hose heater voltage is not within 1.1 to 1.31 V for a continuous 2 s.
MONITORING CONDITIONS
|
P20BF:00
|
Urea hose heater control circuit low input
|
• If any of the following conditions is met under condition A or condition B:
Condition A:
• If the dosing control unit detects that the urea hose heater control circuit voltage is above 0 V and 0.35 V or less for 2 s, the dosing control unit determines that the urea hose heater control circuit has a malfunction.
MONITORING CONDITIONS
Condition B:
• If the dosing control unit detects that the urea hose heater control circuit voltage is more than 1.46 V for 2 s, the dosing control unit determines that the urea hose heater control circuit has a malfunction.
MONITORING CONDITIONS
|
P20C0:00
|
Urea hose heater circuit high input
|
• With all of the following conditions met, the urea hose heater voltage is not within 1.65 to 1.94 V for a continuous 2 s.
MONITORING CONDITIONS
|
P20E8:00
|
Urea pump pressure too low
|
• The dosing control unit detects that the pressure of the urea pump control circuit is less than specified value.
|
P20E9:00
|
Urea pump pressure too high
|
• The dosing control unit detects that the pressure of the urea pump control circuit is more than specified value.
|
P20EA:00
|
SCR relay No.1 malfunction
|
• With the following conditions met, the dosing control unit detects that there is no SCR relay No.1 open signal 3 times or more.
MONITORING CONDITIONS
• Ignition switched ON (engine on)
|
P20EB:00
|
SCR relay No.1 malfunction (stuck closed)
|
• With the following conditions met, the dosing control unit detects that SCR relay No.1 is stuck.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
|
P20EE:00
|
SCR converter efficiency below threshold
|
• The reduction rate of the NOx value detected by the NOx sensor is under 25 % less than the threshold of the reduction rate of the NOx value calculated by the dosing control unit.
|
P20FA:00
|
Open circuit in urea pump circuit
|
• The dosing control unit detects an open circuit for 2 s in the control circuit of the urea pump.
MONITORING CONDITIONS
|
P20FB:00
|
Urea pump (siphoning side) range/performance problem
|
• With any of the following conditions met, the dosing control unit determines that the urea pump (siphoning side) is not operating normally.
MONITORING CONDITIONS
• Urea pump (siphoning side) pressure: 450 kPa {4.59 kgf/cm2, 65.3 psi} or more
• The engine is not running.
• Battery voltage: 10.9—16 V
• The following DTCs are not detected:
|
P20FC:00
|
Urea pump circuit low input
|
• If any of the following conditions is met under condition A or condition B:
Condition A:
• The dosing control unit detects low input for 2 s in the control circuit of the urea pump.
MONITORING CONDITIONS
Condition B:
• The dosing control unit detects low input for 1 s in the control circuit of the urea pump.
MONITORING CONDITIONS
|
P20FD:00
|
Urea pump circuit high input
|
• If any of the following conditions is met under condition A or condition B:
Condition A:
• The dosing control unit detects high input for 2 s in the control circuit of the urea pump.
MONITORING CONDITIONS
Condition B:
• The dosing control unit detects high input for 1 s in the control circuit of the urea pump.
MONITORING CONDITIONS
|
P20FF:00
|
Dosing control unit malfunction
|
• With the following conditions met, there is a malfunction inside the dosing control unit (read/write error, communication error, internal supply voltage malfunction).
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
|
P214F:00
|
Urea tank heater control malfunction
|
• With the following conditions met, the coil conductivity in the urea tank heater is the specified value or more.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• The operation time of the urea tank heater is 50 s or more, or the coil conductivity in the urea tank heater is lower than the value 50 times or more.
• Battery voltage: 8—16 V for a continuous 2 s
• Ignition switched ON (engine off): 5 min or more have elapsed
• The following DTCs are not detected:
|
P21C5:00
|
Urea level sensor: Detection performance malfunction
|
• The dosing control unit detects that the change in the diesel exhaust fluid amount in the urea tank is the specified value or more 4 times.
|
P21CB:00
|
Dosing control unit power supply voltage low input
|
• If the dosing control unit detects that the power supply voltage is less than 8 V for 10 s, the dosing control unit determines that the power supply voltage circuit has a malfunction.
MONITORING CONDITIONS
|
P21CC:00
|
Dosing control unit power supply voltage high input
|
• If the dosing control unit detects that the power supply voltage is more than 16 V for 10 s, the dosing control unit determines that the power supply voltage circuit has a malfunction.
MONITORING CONDITIONS
|
P21DD:00
|
Urea tank heater control malfunction
|
• With the following conditions met, the coil conductivity in the urea tank heater is the specified value or less.
MONITORING CONDITIONS
• Ignition switched ON (engine off or on)
• The operation time of the urea tank heater is 50 s or more, or the coil conductivity in the urea tank heater is lower than the value 50 times or more.
• Battery voltage: 11—16 V for a continuous 2 s
• Ignition switched ON (engine off): 5 min or more have elapsed
• The following DTCs are not detected:
|
P2200:00
|
NOx sensor No.1 control circuit range/performance problem
|
• Any one of the following conditions is met:
|
P2201:00
|
NOx sensor No.1 system: NOx concentration malfunction
|
• With the following conditions met, the value of the NOx sensor No.1 on-board diagnostic result is not within the specified value.
|
P2202:00
|
NOx sensor No.1 (NOx oxygen concentration) circuit low input
|
• The NOx concentration output by NOx sensor No.1 is less than -100 ppm for a continuous 8.0 s.
|
P2203:00
|
NOx sensor No.1 (NOx oxygen concentration) circuit high input
|
• The NOx concentration output by NOx sensor No.1 exceeds 2,900 ppm for a continuous 8.0 s.
|
P2204:00
|
Continuous monitoring of NOx sensor No.1 signal validity
|
• The dosing control unit detects two times that the speed of the signal received from NOx sensor No.1 is slower than the target vehicle speed.
|
P2205:00
|
NOx sensor No.1 heater control circuit range/performance problem
|
• Any one of the following conditions is met:
|
P220A:00
|
NOx sensor No.1: power supply voltage malfunction
|
• The NOx sensor No.1 internal supply voltage is not within the specified value for a continuous 30 s.
|
P220B:00
|
NOx sensor No.2: power supply voltage malfunction
|
• The NOx sensor No.2 internal supply voltage is not within the specified value for a continuous 30 s.
|
P220E:00
|
NOx Sensor No.1 heater: performance problem
|
• The heater built-into NOx sensor No.1 is not activating normally for a continuous 80 s or more.
|
P220F:00
|
NOx Sensor No.2 heater: performance problem
|
• The heater built-into NOx sensor No.2 is not activating normally for a continuous 80 s or more.
|
P221C:00
|
Urea hose heater control circuit low input
|
• The dosing control unit detects that the urea hose heater resistance is specified value or less.
MONITORING CONDITIONS
|
P221D:00
|
Urea hose heater circuit high input
|
• The dosing control unit detects that the urea hose heater resistance is specified value or more.
MONITORING CONDITIONS
|
P2270:00
|
NOx sensor No.2: power supply voltage malfunction
|
• The oxygen concentration output by NOx sensor is higher than the specified value for a continuous 7 s.
|
P2274:00
|
NOx sensor No.2 control circuit range/performance problem
|
• The oxygen concentration output by NOx sensor No.2 is higher than the specified value for a continuous 7 s.
|
P229E:00
|
NOx sensor No.2 control circuit range/performance problem
|
• Any one of the following conditions is met:
|
P229F:00
|
NOx sensor No.2 system: NOx concentration malfunction
|
• With the following conditions met, the value of the NOx sensor No.2 on-board diagnostic result is not within the specified value.
|
P22A0:00
|
NOx sensor No.2 circuit low input
|
• Any one of the following conditions is met:
|
P22A1:00
|
NOx sensor No.2 circuit high input
|
• When any of the following conditions is met:
|
P22A2:00
|
Continuous monitoring of NOx sensor No.2 signal validity
|
• The dosing control unit detects two times that the speed of the signal received from NOx sensor No.2 is slower than the target vehicle speed.
|
P22A3:00
|
NOx sensor No.2 heater control circuit range/performance problem
|
• Any one of the following conditions is met:
|
P24AE:00
|
PM sensor control circuit range/performance problem
|
• The internal circuit voltage or current of the PM sensor is not within the threshold value.
|
P24AF:00
|
PM sensor circuit range/performance
|
• Five s have elapsed since the current in the PM sensor exceeds 5.00 µA.
|
P24B1:00
|
PM sensor circuit high input
|
• The internal circuit voltage of the PM sensor is more than 4.1 V for a continuous 2 s.
|
P24B3:00
|
PM sensor: internal heater circuit current low input
|
• If any of the following conditions is met for a continuous 5 s while the PM sensor internal heater is operating.
|
P24B6:00
|
PM sensor: internal heater circuit current high input
|
• If any of the following conditions is met for a continuous 5 s while the PM sensor internal heater is not operating.
|
P24B7:00
|
PM sensor heater resistance malfunction
|
• PM sensor heater temperature is more than 2.93 Ω or less than 1.93 Ω
|
P24C6:00
|
PM sensor: internal temperature sensor malfunction
|
• When the following condition is met for a continuous 1 s:
|
P24C7:00
|
PM sensor temperature circuit range/performance
|
• The PM temperature detected by the PM sensor is greatly different from the value estimated by the dosing control unit.
• The PM temperature detected by the PM sensor is –39 °C {–39 °F} or less.
|
P24D0:00
|
PM sensor: internal supply voltage malfunction
|
• The PM sensor internal supply voltage is not within the specified value.
|
P24DA:00
|
PM sensor system: Protection tube error
|
• The voltage variance of the heater built into the PM sensor is less than 0.1 V.
|
U0073:00
|
CAN system communication error (HS CAN)
|
• Malfunction in CAN bus communication line.
MONITORING CONDITIONS
• Battery voltage: 10.9—16 V
• Ignition switched ON (engine off or on)
|
U0100:00
|
CAN communication: communication error to PCM
|
• Communication error between the PCM and TCM continues for 5 s or more.
MONITORING CONDITIONS
• Battery voltage: 10.9—16 V
• Ignition switched ON (engine off or on)
|
U029D:00
|
CAN communication system: NOx sensor No.1 information communication error with dosing control unit
|
• With the following conditions met, a communication error between the dosing control unit and NOx sensor No.1 is continued for 5 s or more.
MONITORING CONDITIONS
• Battery voltage: 10.9—16 V
• Ignition switched ON (engine off or on)
|
U029E:00
|
CAN communication system: NOx sensor No.2 information communication error with dosing control unit
|
• With the following conditions met, a communication error between the dosing control unit and NOx sensor No.2 is continued for 5 s or more.
MONITORING CONDITIONS
• Battery voltage: 10.9—16 V
• Ignition switched ON (engine off or on)
|
U02A2:00
|
SENT communication system: urea quality sensor information communication error with dosing control unit
|
• With the following conditions met, a communication error between the dosing control unit and is continued for 5 s or more.
MONITORING CONDITIONS
• Battery voltage: 10.9—16 V
• Ignition switched ON
|
U02A3:00
|
CAN communication system: PM sensor information communication error with dosing control unit
|
• With the following conditions met, a communication error between the dosing control unit and PM sensor is continued for 5 s or more.
MONITORING CONDITIONS
• Battery voltage: 10.9—16 V
• Ignition switched: On
|
Sending continuous monitoring system test results (pending code)
Snapshot data
Snapshot data table
Snapshot data item |
Unit |
Definition |
Data read/use method |
Corresponding PID data monitor item |
---|---|---|---|---|
CTRL_MOD_VOL
|
V
|
Dosing control unit voltage
|
—
|
—
|
RE_TANK_LV_SUP
|
—
|
Urea tank level supported
|
—
|
—
|
RE_TANK_LV
|
%
|
Urea tank level
|
—
|
—
|
Sending diagnostic data
PID/DATA monitor item table
Item (definition) |
Unit/Condition |
Definition |
---|---|---|
A_SCR_C_TMP
|
°C, °F
|
Average SCR catalyst temperature
|
C_T_B1S2
|
°C, °F
|
Exhaust gas temperature sensor No.2
|
CL_NMHC_MN_CP
|
—
|
Catalyst monitoring completed / NMHC catalyst monitoring completed
|
CMP_MNT_ENA
|
—
|
Comprehensive component monitoring enabled
|
COMP3_MNT
|
—
|
Comprehensive component monitoring completed
|
CONF_URA_TK_LV
|
—
|
Configuration for urea tank level
|
CP_IGN_SP
|
—
|
Compression ignition monitoring supported
|
CTLY_NMHC_MN
|
—
|
Catalyst monitoring / NMHC catalyst monitoring
|
CTRL_MOD_VOL
|
V
|
Control module voltage
|
DC_PWM_O_PS_UV
|
%
|
Dutycycle of the PWM signal output to the power stage of urea dosing valve
|
DIS_ACT_MIL
|
km, ft, mi
|
Distance traveled while check engine light is activated
|
DIS_CLR_DTC
|
km, ft, mi
|
Distance Since DTCs cleared
|
DPES_DS_NOX
|
—
|
Dew point end signal for downstream NOx sensor
|
DPES_PM
|
—
|
Dew point end signal for PM sensor
|
DPES_US_NOX
|
—
|
Dew point end signal for upstream NOx sensor
|
DSR_D_AMO
|
— (mg/s)
|
Desired dosing amount
|
EG_MF
|
— (kg/h)
|
Exhaust gas mass flow
|
EGR_VVT_MCC
|
— (Undefined/Not Used)
|
EGR and/or VVT monitor completion condition counts
|
EGR_VVT_MCEC
|
— (Undefined/Not Used)
|
EGR and/or VVT monitor conditions encountered counts
|
EGR_VVT_MN_CP
|
—
|
EGR and/or VVT system monitoring completed
|
EGR_VVT_MNT
|
—
|
EGR and/or VVT system monitoring
|
EGS_MCC
|
— (Undefined/Not Used)
|
Gas sensor monitor completion counts
|
EGS_MCEC
|
— (Undefined/Not Used)
|
Exhaust gas sensor monitor conditions encountered counts
|
EIAECD1_TT_SUP
|
—
|
Total run time with EI-AECD #1 active supported
|
EIAECD1_TT_TM1
|
hh:mm:ss
|
Total run time with EI-AECD #1 Timer 1 active
|
EIAECD1_TT_TM2
|
hh:mm:ss
|
Total run time with EI-AECD #1 Timer 2 active
|
EIAECD2_TT_SUP
|
—
|
Total run time with EI-AECD #2 active supported
|
EIAECD2_TT_TM1
|
hh:mm:ss
|
Total run time with EI-AECD #2 Timer 1 active
|
EIAECD2_TT_TM2
|
hh:mm:ss
|
Total run time with EI-AECD #2 Timer 2 active
|
EIAECD3_TT_SUP
|
—
|
Total run time with EI-AECD #3 active supported
|
EIAECD3_TT_TM1
|
hh:mm:ss
|
Total run time with EI-AECD #3 Timer 1 active
|
EIAECD3_TT_TM2
|
hh:mm:ss
|
Total run time with EI-AECD #3 Timer 2 active
|
EIAECD4_TT_SUP
|
—
|
Total run time with EI-AECD #4 active supported
|
EIAECD4_TT_TM1
|
hh:mm:ss
|
Total run time with EI-AECD #4 Timer 1 active
|
EIAECD4_TT_TM2
|
hh:mm:ss
|
Total run time with EI-AECD #4 Timer 2 active
|
EIAECD5_TT_SUP
|
—
|
Total run time with EI-AECD #5 active supported
|
EIAECD5_TT_TM1
|
hh:mm:ss
|
Total run time with EI-AECD #5 Timer 1 active
|
EIAECD5_TT_TM2
|
hh:mm:ss
|
Total run time with EI-AECD #5 Timer 2 active
|
EVAP_SYS_MN
|
—
|
Evaporative system monitoring
|
EVAP_SYS_MN_CP
|
—
|
Evaporative system monitoring completed
|
FU_SYS_CP
|
—
|
Fuel system monitoring completed
|
FU_SYS_ENA
|
—
|
Fuel system monitoring enabled
|
FUEL_MCC
|
— (Undefined/Not Used)
|
Fuel monitor completion condition counts
|
FUEL_MCEC
|
— (Undefined/Not Used)
|
Fuel monitor conditions encountered counts
|
HT_NOX_SRC_MN
|
—
|
Heated catalyst monitoring / NOx/SCR aftertreatment monitoring
|
HTR_TANK
|
Off/On
|
Urea tank heater
|
IGN_CYCL_CNT
|
— (Undefined/Not Used)
|
Ignition cycle counter
|
INTG_D_MFB
|
— (g)
|
Integrated dosing mass feedback
|
IP_C_HT_HCU
|
— (mA)
|
Input current of heater from HCU
|
LLMD_SIG2_DNOX
|
—
|
Linear lambda signal of 2. downstream Nox sensor from CAN
|
MSF_CP
|
—
|
Misfire monitoring completed
|
MSF_ENA
|
—
|
Misfire monitoring enabled
|
NMHC_C_MCC
|
— (Undefined/Not Used)
|
NMHC catalyst monitor completion counts
|
NMHC_C_MCEC
|
— (Undefined/Not Used)
|
NMHC catalyst monitor conditions encountered counts
|
NO_DTM_CCT
|
— (ppm)
|
The determined NOx concentration
|
NOX_ADS_MCC
|
— (Undefined/Not Used)
|
NOx adsorber monitor completion condition counts
|
NOX_ADS_MCEC
|
— (Undefined/Not Used)
|
NOx adsorber monitor conditions encountered counts
|
NOX_C_B1S1
|
— (ppm)
|
The exhaust gas NOx concentration before SCR converter
|
NOX_C_B1S1_SUP
|
—
|
The exhaust gas NOx concentrationby NOx sensor No.1 supported
|
NOX_C_B1S2
|
— (ppm)
|
The exhaust gas NOx concentration after SCR converter
|
NOX_C_B1S2_SUP
|
—
|
The exhaust gas NOx concentrationby NOx sensor No.2 supported
|
NOX_C_B2S1
|
— (ppm)
|
The exhaust gas NOx concentration before SCR converter
|
NOX_C_B2S1_SUP
|
—
|
The exhaust gas NOx concentrationby NOx sensor No.1 supported
|
NOX_C_B2S2
|
— (ppm)
|
The exhaust gas NOx concentration after SCR converter
|
NOX_C_B2S2_SUP
|
—
|
The exhaust gas NOx concentrationby NOx sensor No.2 supported
|
NOX_CCT_ATO1
|
— (ppm)
|
NOx Concentration from ATO1
|
NOX_SCR_C_MCC
|
— (Undefined/Not Used)
|
NOx/SCR Catalyst Monitor Completion condition counts
|
NOX_SCR_C_MCEC
|
— (Undefined/Not Used)
|
NOx/SCR Catalyst Monitor Conditions encountered counts
|
NOX_SIG_ATO1
|
—
|
NOx signal status from ATO1
|
NOX_SRC_MN_CP
|
—
|
Heated catalyst monitoring completed / NOx/SCR aftertreatment monitoring completed
|
NOX_ST_SEN_SIG
|
—
|
Status of NOx sensor signal
|
O2_CCT_ATO1
|
—
|
Oxygen Concentration from ATO1
|
O2_SH_PM_F
|
—
|
Oxygen sensor heater monitoring / PM filter monitoring
|
O2_SH_PM_F_CP
|
—
|
Oxygen sensor heater monitoring completed / PM filter monitoring completed
|
O2_SIG_ST_ATO1
|
—
|
Oxygen signal status from ATO1
|
O2_SM_EGSM
|
—
|
Oxygen sensor monitoring/exhaust gas sensor monitoring
|
O2_SM_EGSM_CP
|
—
|
Oxygen sensor monitoring completed/exhaust gas sensor monitoring completed
|
OBD_MCEC
|
— (Undefined/Not Used)
|
OBD Monitoring conditions encountered counts
|
OP_ADC
|
— (mA)
|
OP of the ADC
|
OP_F_ACT_PS
|
— (Hz)
|
Output frequency for activation of the power stage
|
OP_S_FL_H_MM
|
— (mm, in)
|
Output signal of the fill level height in mm
|
PMF_MCC PM
|
— (Undefined/Not Used)
|
Filter monitor completion condition counts
|
PMF_MCEC
|
— (Undefined/Not Used)
|
PM filter monitor conditions encountered counts
|
PMS_A_B1S1
|
—
|
PM sensor active status bank 1 sensor 1
|
PMS_NO_B1S1
|
— (%)
|
The PM sensor output value
|
PMS_O_B1S1_SUP
|
—
|
PM sensor operating status bank 1 sensor 1 supported
|
PMS_O_B2S1_SUP
|
—
|
PM sensor operating status bank 2 sensor 1 supported
|
PMS_R_B1S1
|
—
|
PM sensor regen status bank 1 sensor 1
|
PMS_S_B1S1_SUP
|
—
|
PM sensor signal bank 1 sensor 1 supported
|
PMS_S_B2S1_SUP
|
—
|
PM sensor signal bank 2 sensor 1 supported
|
RDC_PMP_DC_CM
|
—
|
Reductant pump duty cycle - commanded
|
RDCT_INJ_DUCY
|
%
|
Reductant injector duty cycle
|
RDCT_LINE_HEAT
|
—
|
Reductant line heater
|
RDCT_RVDC_CMD
|
%
|
Reductant reverting valve duty cycle - commanded
|
RDCT_TANK_HEAT
|
—
|
Reductant tank heater
|
RE_TANK_LV
|
%
|
Reagent tank level
|
RE_TANK_LV_SUP
|
—
|
Reagent tank level supported
|
REDUCT_INJ_DC
|
%
|
Reductant injector duty cycle
|
REV_VALVE
|
Off/On
|
Urea reverting valve
|
RLA_UR_PMP_PRE
|
— (hPa)
|
Urea pump module pressure
|
RMN_DF_TM_PR_L
|
— (s)
|
Remaining defrosting time of the pressure line
|
RMN_DF_TM_TK
|
— (s)
|
Remaining defrosting time of the tank
|
RMN_ML_DIRC
|
— (km mile)
|
Remaining mileage dircetly based on reducing agent in tank
|
RMN_TM_SP_DF
|
— (s)
|
Remaining time for supply module defrost
|
RRDC_AG_RMN
|
— (%)
|
Remaining quantity of reducing agent
|
S_LLMD_V2_DNOX
|
—
|
State of lin lambda value of 2.downstream NOx sensor
|
S_STT_HYD_SCR
|
—
|
Substate of hydraulic SCR-system
|
S_UR_TANK_TMP
|
°C, °F
|
Sensed urea tank temperature
|
SDARS_BSPR_CP
|
—
|
Secondary air system monitoring completed/boost pressure system monitoring completed
|
SDARS_BSTPRE
|
—
|
Secondary air system monitoring/boost pressure system monitoring
|
SPDC_URDC
|
%
|
Set-point dutycycle from urea dosing controller
|
ST_DF_CHK
|
—
|
State of the defrosting check
|
ST_OP_S_PRE_HT
|
—
|
Status of output stage pressure heater
|
ST_OP_S_TK_HT
|
—
|
Status of output stage tank heater
|
STT_HYD_SCR
|
—
|
State of hydraulic SCR-system
|
VOLRDC_AG_RMN
|
— (l)
|
Remaining quantity of reducing agent [l]
|
On-board device control (Simulation test, active command mode)
Simulation item table
Item (definition) |
Unit/Condition |
Definition |
Operation condition |
---|---|---|---|
HTR_LINE
|
Off/On
|
Urea hose heater
|
• Under the following conditions:
|
HTR_TANK
|
Off/On
|
Urea tank heater
|
• Under the following conditions:
|
RDC_PMP_DC_CM
|
—
|
Urea pump duty cycle
|
• Under the following conditions:
|
REDUCT_INJ_DC
|
%
|
Reductant injector duty cycle
|
• Under the following conditions:
|
REV_VALVE
|
Off/On
|
Urea reverting valve
|
• Under the following conditions:
|