COOLANT CONTROL VALVE [SKYACTIV-G 2.5 (WITH CYLINDER DEACTIVATION)]


id0112q6158800


Outline

•  The coolant control valve adjusts the coolant control valve opening angle and supplies engine coolant to the appropriate engine coolant passage according to the engine load conditions.
•  Further engine warming has been promoted by blocking each water passage while the engine is cool.

Construction

•  The coolant control valve is located on the left side of the engine.
ac5uun00003736
•  The coolant control valve feeds engine coolant via 3 engine coolant passages.
Note
•  The thermostat is integrated with the water flow control valve. When the engine coolant temperature exceeds the specification, engine coolant is forced to flow into the radiator.
ac5wzn00004572
•  Engine coolant flows constantly in coolant passage (1).
•  At coolant passages (2) and (3), engine coolant flows when the rotor rotates and the rotor opening is aligned to each engine coolant passage outlet.
•  The PCM adjusts the coolant control valve opening angle and switches the engine coolant passage according to changes in the engine coolant temperature. For details, refer to the [WATER FLOW CONTROL]. (See WATER FLOW CONTROL [SKYACTIV-G 2.5 (WITH CYLINDER DEACTIVATION)].)
ac5wzn00004597