COOLING FAN MOTOR INSPECTION [SKYACTIV-D 2.2]


id0112s6801800


ATX

Note
•  The cooling fan motor cannot be removed as a single unit. If the cooling fan motor is replaced, replace the cooling fan component.

DTC inspection

1.  Connect the M-MDS to the DLC-2.

2.  Perform the DTC inspection using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST [PCM (SKYACTIV-D 2.2)].)

•  If any DTC related to the cooling fan motor is present, repair the malfunctioning location according to the applicable DTC troubleshooting. (See DTC TABLE [PCM (SKYACTIV-D 2.2)].)


MTX


Part inspection

1.  Verify that the battery is fully charged. (See BATTERY INSPECTION.)

2.  Disconnect the cooling fan motor connector (fan control module side, 2 terminals).

3.  Install a tester and battery to the cooling fan motor connector (2 terminals) as shown in the figure.

am6zzw00017094

4.  Verify that each cooling fan motors operate smoothly at the standard current.

•  If there is any malfunction, replace the applicable part.
Cooling fan motor No.1, No.2 standard current
15—21 A [12 V]