DTC U3000:42 [INSTRUMENT CLUSTER (TPMS)]
id020210811900
DTC |
U3000:42 |
Instrument cluster internal malfunction |
---|---|---|
DETECTION CONDITION
|
• Instrument cluster internal malfunction is detected.
|
|
FAIL-SAFE FUNCTION
|
• Refer to “Fail-safe function table”. (See DTC TABLE [INSTRUMENT CLUSTER (TPMS)].)
|
|
POSSIBLE CAUSE
|
• Instrument cluster malfunction
|
|
SYSTEM WIRING DIAGRAM
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
VERIFY INSTRUMENT CLUSTER DTC
• Using the M-MDS, clear the DTC from the instrument cluster.
• Using the M-MDS, perform the instrument cluster DTC inspection.
• Is the same Pending DTC present?
|
Yes
|
Replace the instrument cluster, then go to the next step.
|
No
|
Go to the next step.
|
||
2
|
VERIFY NO DTC IS PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|