DTC U3000:42 [INSTRUMENT CLUSTER (TPMS)]


id020210811900

DTC

U3000:42

Instrument cluster internal malfunction

DETECTION CONDITION
•  Instrument cluster internal malfunction is detected.
FAIL-SAFE FUNCTION
•  Refer to “Fail-safe function table”. (See DTC TABLE [INSTRUMENT CLUSTER (TPMS)].)
POSSIBLE CAUSE
•  Instrument cluster malfunction
SYSTEM WIRING DIAGRAM
Not applicable


Diagnostic Procedure

Step

Inspection

Action

1
VERIFY INSTRUMENT CLUSTER DTC
•  Using the M-MDS, clear the DTC from the instrument cluster.
•  Using the M-MDS, perform the instrument cluster DTC inspection.
•  Is the same Pending DTC present?
Yes
Replace the instrument cluster, then go to the next step.
No
Go to the next step.
2
VERIFY NO DTC IS PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.