PID/DATA MONITOR TABLE [SAS CONTROL MODULE (ACTIVE BONNET)]
id0802h4081000
PID |
Unit/Condition |
Data contents |
SAS control module terminal |
|
---|---|---|---|---|
PCD_A
(Poorly connected detector bar terminal voltage nominal (SAS control module connector A))
|
V
|
• Normal connected: 0.27 V or less
• Poor connected: 3.17 V or more
|
1a, 1b
|
|
PCD_B
(Poorly connected detector bar terminal voltage nominal (SAS control module connector B))
|
V
|
• Normal connected: 0.27 V or less
• Poor connected: 3.17 V or more
|
2a, 2b
|
|
PCD_C
(Poorly connected detector bar terminal voltage nominal (SAS control module connector C))
|
V
|
• Normal connected: 0.27 V or less
• Poor connected: 3.17 V or more
|
3a, 3b
|
|
RES_ACTU1
(Active bonnet actuator (RH) resistance nominal)
|
ohm
|
Continuous: 0.88–10.53 ohms
|
1U, 1W
|
|
RES_ACTU2
(Active bonnet actuator (LH) resistance nominal)
|
ohm
|
Continuous: 0.88–10.53 ohms
|
1Z, 1AA
|
|
VPWR_IGA
(SAS control module power voltage)
|
V
|
Ignition is switched ON: IG1 voltage
|
2AD
|