PID/DATA MONITOR TABLE [SAS CONTROL MODULE (ACTIVE BONNET)]


id0802h4081000

PID

Unit/Condition

Data contents

SAS control module terminal

PCD_A
(Poorly connected detector bar terminal voltage nominal (SAS control module connector A))
V
•  Normal connected: 0.27 V or less
•  Poor connected: 3.17 V or more
1a, 1b
PCD_B
(Poorly connected detector bar terminal voltage nominal (SAS control module connector B))
V
•  Normal connected: 0.27 V or less
•  Poor connected: 3.17 V or more
2a, 2b
PCD_C
(Poorly connected detector bar terminal voltage nominal (SAS control module connector C))
V
•  Normal connected: 0.27 V or less
•  Poor connected: 3.17 V or more
3a, 3b
RES_ACTU1
(Active bonnet actuator (RH) resistance nominal)
ohm
Continuous: 0.88–10.53 ohms
1U, 1W
RES_ACTU2
(Active bonnet actuator (LH) resistance nominal)
ohm
Continuous: 0.88–10.53 ohms
1Z, 1AA
VPWR_IGA
(SAS control module power voltage)
V
Ignition is switched ON: IG1 voltage
2AD