LUMBAR SUPPORT MOTOR INSPECTION
id091300804300
L.H.D.
1. Disconnect the negative battery terminal and wait for 1 min or more.(See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Slide hooks A in the order of arrows (1), (2), (3) shown in the figure and disconnect them from hooks B.
ac5uuw00002049
|
3. Open fasteners.
am6zzw00012365
|
4. Disconnect the lumber support motor connector.
am6zzw00017433
|
Front seat operation |
Connection |
|
---|---|---|
A |
B |
|
Forward
|
GND
|
B+
|
Backward
|
B+
|
GND
|
R.H.D.
1. Disconnect the negative battery terminal and wait for 1 min or more. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Slide hooks A in the order of arrows (1), (2), (3) shown in the figure and disconnect them from hooks B.
ac5uuw00002049
|
3. Open fasteners.
am6zzw00012365
|
4. Disconnect the lumber support motor connector.
am6zzw00017434
|
Front seat operation |
Connection |
|
---|---|---|
A |
B |
|
Forward
|
B+
|
GND
|
Backward
|
GND
|
B+
|