PID/DATA MONITOR INSPECTION [WITH i-ELOOP (SKYACTIV-G 2.0, SKYACTIV-G 2.5)]


id130205000500

1.  Connect the M-MDS to the DLC-2.

2.  After the vehicle is identified, select the following items from the initialization screen of the M-MDS.

(1)  Select “DataLogger”.
(2)  Select “Modules”.
(3)  Select “DCDC”.

3.  Select the applicable PID from the PID table.

4.  Verify the PID data according to the directions on the screen.

Note
•  The PID data screen function is used for monitoring the calculated value of input/output signals in the module. Therefore, if the monitored value of the output component is not within the specification, it is necessary to inspect the monitored value of input component corresponding to the applicable output part control. In addition, because the system does not display an output part malfunction as an abnormality in the monitored value, it is necessary to inspect the output component individually.
•  When detecting DTCs, PIDs related to a malfunctioning system may not display even if the module is normal. Therefore, if a PID is not displayed, it is necessary to verify the DTC, perform malfunction diagnosis of the DTC that was detected, and do repairs.
•  The [Type] in the PID/data monitor table is indicated as follows.
―  Input: Value input to module
―  Conversion: Value converted into value input to module
―  Calculation: Value calculated for several input values in module
―  Output: Value output by module

—: Not applicable

Item

Unit/Condition

Type

Description

Condition/Specification (Reference)

BYPS_RLY_STAT1
Close/OPEN
Input
Displays the bypass relay connection request reception status. The DC-DC convertor (i-ELOOP) receives a bypass relay connection request from the PCM via CAN communication.
•  Close: Bypass relay connection request is received
•  OPEN: Bypass relay connection is not received
BYPS_STAT
Disconect (Off)/Conect (On)/Fault (Off)/Fault (On)
Output
Bypass relay operation status
•  Displays the bypass relay status.
―  Disconect (Off): Bypass Off
―  Conect (On): Bypass On
―  Fault (Off): Off fault
―  Fault (On): On fault
CAP_V
V
Input
Capacitor voltage
•  Displays the capacitor voltage.
CAPA_IN_C
F
Conversion
Displays the capacitor (i-ELOOP) actual capacitance.
•  Displays the capacitor (i-ELOOP) actual capacitance.
CAPA_IN_R
ohm
Conversion
Displays the capacitor (i-ELOOP) actual internal resistance.
•  Displays the capacitor (i-ELOOP) actual internal resistance.
CAPA_TEMP
°C, °F
Conversion
Displays the capacitor (i-ELOOP) temperature.
•  Displays the capacitor (i-ELOOP) temperature.
CAPA_UL_V
V
Calculation
Displays the capacitor (i-ELOOP) output voltage.
•  Switch ignition ON (engine off): Approx. 16.00 V
•  Idle: Approx. 16.00 V
•   Racing (engine speed above 2,000 rpm): Approx. 14.64 V
CHRAG_WAR_REQ
Request/Not Request/
Output
Displays the charging system warning light illumination request send status. The DC-DC convertor (i-ELOOP) sends a charging system warning light illumination request to the instrument cluster via CAN communication.
•  Request: Charging system warning light illumination request is sent
•  Not Request: Charging system warning light illumination request is not sent
CONV_OUT_V
V
Input
Voltage reduction circuit output voltage
•  Displays the voltage reduction circuit output voltage.
CONV_STAT
Ready/Power Output(Idle)/Power Output(Normal)/Power Output(Limit)/Safe Mode/Power Output(Stop)/Error/Initializing
Output
DC-DC converter (i-ELOOP) internal voltage reduction circuit operation status
•  Displays the voltage reduction circuit operation status.
―  Preparation for voltage reduction completed: Ready
―  Output idle status: Power Output(Idle)
―  During output: Power Output (Normal)
―  Target output value not achieved due to limit: Power Output (Limit)
―  Shut down: Power Output(Stop)
―  Self-protection status (voltage reduction circuit inoperable): Safe Mode
―  Voltage reduction circuit malfunction: Error
―  During Initializing: Initializing
CRNK_STAT
Close/OPEN
Input
•  Displays in the M-MDS but it does not operate.
DCDC_IN_V
V
Input
DC-DC converter (i-ELOOP) input voltage
•  Displays the DC-DC converter (i-ELOOP) input voltage.
DCDC_OUT_I
A
Input
DC-DC converter (i-ELOOP) output current
•  Displays the DC-DC converter (i-ELOOP) output current.
DCDC_OUT_V
V
Input
DC-DC converter (i-ELOOP) output voltage
•  Displays the DC-DC converter (i-ELOOP) output voltage.
DCDC_TEMP
°C, °F
Conversion
Displays the DC-DC converter (i-ELOOP) temperature.
•  Displays the DC-DC converter (i-ELOOP) temperature.
DEGEN_COUNT
Output
Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
•  Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
DEGEN_WARN
OK/Degeneration warning/Degeneration/Degeneracy Stop
Output
Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
•  Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
IR_SW_STAT
Connect (On)/Disconnect (Off)/Fault (On)/Fault (Off)
Output
i-stop relay operation status
•  Displays the i-stop relay operation status.
―  i-stop relay on: Connect (On)
―  i-stop relay off: Disconnect (Off)
―  i-stop relay on is malfunctioning: Fault (On)
―  i-stop relay off is malfunctioning: Fault (Off)
I-STOP_REQ
Request/Not Request
Output
Displays the i-stop inhibit request send status. The DC-DC convertor (i-ELOOP) sends an i-stop inhibit request to the PCM via CAN communication.
•  Request: i-stop inhibit request is sent
•  Not Request: i-stop inhibit request is not sent
MAS_WARN
On/Off
Output
Displays the master warning light illumination request send status. The DC-DC convertor (i-ELOOP) sends a master warning light illumination request to the instrument cluster via CAN communication.
•  On: Master warning light illumination request is sent
•  Off: Master warning light illumination request is not sent
Nzero_Limit_REQ
NORMAL/Fail
Calculation
•  Displays in the M-MDS but it does not operate.
ODR_STOR_REQ
Request/Not Request
Input
Displays the presence/non-presence of the data storage request signal to the PCM.
•  Request: Data storage request is sent
•  Not Request: Data storage request is not sent
PRECHG_WARN
Off/On
Output
Pre-charge warning indication request to instrument cluster
•  Displays the pre-charge warning indication request to the instrument cluster.
SAFE_M_COUNT
Calculation
Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
•  Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).