PID/DATA MONITOR INSPECTION [WITH i-ELOOP (SKYACTIV-G 2.0, SKYACTIV-G 2.5)]
id130205000500
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
3. Select the applicable PID from the PID table.
4. Verify the PID data according to the directions on the screen.
Item |
Unit/Condition |
Type |
Description |
Condition/Specification (Reference) |
---|---|---|---|---|
BYPS_RLY_STAT1
|
Close/OPEN
|
Input
|
Displays the bypass relay connection request reception status. The DC-DC convertor (i-ELOOP) receives a bypass relay connection request from the PCM via CAN communication.
|
• Close: Bypass relay connection request is received
• OPEN: Bypass relay connection is not received
|
BYPS_STAT
|
Disconect (Off)/Conect (On)/Fault (Off)/Fault (On)
|
Output
|
Bypass relay operation status
|
• Displays the bypass relay status.
|
CAP_V
|
V
|
Input
|
Capacitor voltage
|
• Displays the capacitor voltage.
|
CAPA_IN_C
|
F
|
Conversion
|
Displays the capacitor (i-ELOOP) actual capacitance.
|
• Displays the capacitor (i-ELOOP) actual capacitance.
|
CAPA_IN_R
|
ohm
|
Conversion
|
Displays the capacitor (i-ELOOP) actual internal resistance.
|
• Displays the capacitor (i-ELOOP) actual internal resistance.
|
CAPA_TEMP
|
°C, °F
|
Conversion
|
Displays the capacitor (i-ELOOP) temperature.
|
• Displays the capacitor (i-ELOOP) temperature.
|
CAPA_UL_V
|
V
|
Calculation
|
Displays the capacitor (i-ELOOP) output voltage.
|
• Switch ignition ON (engine off): Approx. 16.00 V
• Idle: Approx. 16.00 V
• Racing (engine speed above 2,000 rpm): Approx. 14.64 V
|
CHRAG_WAR_REQ
|
Request/Not Request/
|
Output
|
Displays the charging system warning light illumination request send status. The DC-DC convertor (i-ELOOP) sends a charging system warning light illumination request to the instrument cluster via CAN communication.
|
• Request: Charging system warning light illumination request is sent
• Not Request: Charging system warning light illumination request is not sent
|
CONV_OUT_V
|
V
|
Input
|
Voltage reduction circuit output voltage
|
• Displays the voltage reduction circuit output voltage.
|
CONV_STAT
|
Ready/Power Output(Idle)/Power Output(Normal)/Power Output(Limit)/Safe Mode/Power Output(Stop)/Error/Initializing
|
Output
|
DC-DC converter (i-ELOOP) internal voltage reduction circuit operation status
|
• Displays the voltage reduction circuit operation status.
|
CRNK_STAT
|
Close/OPEN
|
Input
|
• Displays in the M-MDS but it does not operate.
|
|
DCDC_IN_V
|
V
|
Input
|
DC-DC converter (i-ELOOP) input voltage
|
• Displays the DC-DC converter (i-ELOOP) input voltage.
|
DCDC_OUT_I
|
A
|
Input
|
DC-DC converter (i-ELOOP) output current
|
• Displays the DC-DC converter (i-ELOOP) output current.
|
DCDC_OUT_V
|
V
|
Input
|
DC-DC converter (i-ELOOP) output voltage
|
• Displays the DC-DC converter (i-ELOOP) output voltage.
|
DCDC_TEMP
|
°C, °F
|
Conversion
|
Displays the DC-DC converter (i-ELOOP) temperature.
|
• Displays the DC-DC converter (i-ELOOP) temperature.
|
DEGEN_COUNT
|
—
|
Output
|
Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
|
• Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
|
DEGEN_WARN
|
OK/Degeneration warning/Degeneration/Degeneracy Stop
|
Output
|
Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
|
• Displays the control status due to high temperature in the DC-DC converter (i-ELOOP).
|
IR_SW_STAT
|
Connect (On)/Disconnect (Off)/Fault (On)/Fault (Off)
|
Output
|
i-stop relay operation status
|
• Displays the i-stop relay operation status.
|
I-STOP_REQ
|
Request/Not Request
|
Output
|
Displays the i-stop inhibit request send status. The DC-DC convertor (i-ELOOP) sends an i-stop inhibit request to the PCM via CAN communication.
|
• Request: i-stop inhibit request is sent
• Not Request: i-stop inhibit request is not sent
|
MAS_WARN
|
On/Off
|
Output
|
Displays the master warning light illumination request send status. The DC-DC convertor (i-ELOOP) sends a master warning light illumination request to the instrument cluster via CAN communication.
|
• On: Master warning light illumination request is sent
• Off: Master warning light illumination request is not sent
|
Nzero_Limit_REQ
|
NORMAL/Fail
|
Calculation
|
• Displays in the M-MDS but it does not operate.
|
|
ODR_STOR_REQ
|
Request/Not Request
|
Input
|
Displays the presence/non-presence of the data storage request signal to the PCM.
|
• Request: Data storage request is sent
• Not Request: Data storage request is not sent
|
PRECHG_WARN
|
Off/On
|
Output
|
Pre-charge warning indication request to instrument cluster
|
• Displays the pre-charge warning indication request to the instrument cluster.
|
SAFE_M_COUNT
|
—
|
Calculation
|
Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
|
• Displays the number of times the system switches to safe mode due to high temperature in the DC-DC converter (i-ELOOP).
|