1. Follow "BEFORE REPAIR PROCEDURE" before performing any work operations to prevent fuel from spilling from the fuel system. (See BEFORE REPAIR PROCEDURE [MZR-CD (RF Turbo)].)
2. Disconnect the negative battery cable.
3. Remove the fuel tank. (See FUEL TANK REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)
4. Plug the fuel pipe of the fuel gauge sender unit.
5. Plug port C.
6. Connect the pump to port B.
7. Level the fuel tank.
8. Apply pressure of +2.0 kpa {+34 mmHg, +1.3 inHg} to port B.
9. Apply pressure of -5.9 kPa {-44 mmHg, -1.7 inHg} to port B.
10. Apply pressure of +2.0 kPa {+15 mmHg, +0.6 inHg} to port B.