NONRETURN VALVE INSPECTION [MZR-CD (RF Turbo)]


id0114f1803600

Note
• Nonreturn valve is integrated in the fuel tank. Therefore, before inspecting the nonreturn valve perform the following:

1. Remove the fuel gauge sender unit. (See FUEL TANK REMOVAL/INSTALLATION [MZR-CD (RF Turbo)].)

2. Siphon the fuel from the fuel tank.

Note
• The nonreturn valve is normally closed by the spring force.

3. Verify that the nonreturn valve is closed.

• If it is stuck open, replace the fuel tank.

4. Verify that the nonreturn valve opens when pulled up by a finger.

• If it does not open, replace the nonreturn valve.