FUEL PUMP CONTROL OPERATION [L3 Turbo]


id0140b6102200

Operation Condition

• When the ignition switch is turned to the ON position, the PCM turns the fuel pump relay on for 1 s, then off.
• When it is detected that the NE signal rises during cranking, the fuel pump relay turns on.
• When the engine is stopped, the fuel pump relay turns off.

Operation Inhibition Condition

• When receiving an engine stop request signal from the immobilizer system, the PCM force-stops control of the fuel injectors. As a result, the engine does not start.

1
Engine stop request signal received
2
From ignition switch
3
From battery
4
Fuel pump relay
5
Fuel pump
6
Engine stop request signal not received