SIMULATION FUNCTION [FS5A-EL]


id050221100800

• By using the WDS or equivalent, simulation items for input/output parts preset in the TCM can be optionally selected and operated regardless of TCM control conditions.

Simulation Item Table

X: Available

Simulation item

Applicable component

Unit/Condition

Operation

TCM terminal

IG ON

Idle

LPS
Pressure control solenoid control A signal in TCM
%
 
X
1E 1G
LPS B
Pressure control solenoid control B signal in TCM
%
 
X
1D
SSA/SS1
Shift solenoid A control signal in TCM
%
 
X
1A
SSB/SS2
Shift solenoid B control signal in TCM
%
 
X
1B
SSC/SS3
Shift solenoid C control signal in TCM
%
 
X
1C
SSD/SS4
Shift solenoid D control signal in TCM
On/Off
 
X
1F
SSE_SS5
Shift solenoid E control signal in TCM
On/Off
 
X
1H
SSF_SS6
Shift solenoid F control signal in TCM
On/Off
 
X
1J