DTC 21


id070200803300

DTC 21

Airflow mode actuator (potentiometer) (present)

POSSIBLE CAUSE

• Airflow mode actuator malfunction
• Climate control unit malfunction
• Open circuit between airflow mode actuator and climate control unit
• Short circuit between airflow mode actuator (terminal C) and climate control unit (terminal 1W: 24-pin)

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
• Inspect airflow mode actuator.
• Is it okay?
Yes
Go to the next step.
No
Replace airflow mode actuator.
2
• Disconnect air mix actuator connector.
• Is resistance between terminals 1W and 1I of climate control unit connector (24-pin) more than 387 ohms?
Yes
Go to the next step.
No
Repair wiring harness. (Short circuit)
3
• Disconnect climate control unit connector (24-pin).
• Is resistance between terminals 1B and 1I of climate control unit connector (24-pin) less than 4.8 kilohms?
Yes
Go to the next step.
No
Repair wiring harness. (Open circuit)
4
• Is resistance between terminals 1B and 1W of climate control unit connector (24-pin) less than 4.2 kilohms?
Yes
Replace climate control unit.
No
Repair wiring harness. (Open circuit)