DTC No.
|
Indicator pattern
|
Diagnosed circuit
|
Detected condition
|
Memo rized
|
|
02
|
|
Solar radiation sensor (present)
|
Open circuit in solar radiation sensor circuit
Short circuit in solar radiation sensor circuit (terminal B side only)
|
No
|
|
06
|
|
Cabin temperature sensor (present)
|
Open/short circuit is in cabin temperature sensor circuit
|
No
|
|
07
|
|
Cabin temperature sensor (past)
|
Cabin temperature sensor circuit is entered fail-safe mode at least once
|
Yes
|
|
10
|
|
Evaporator temperature sensor (present)
|
Open/short circuit is in evaporator temperature sensor circuit
|
No
|
|
11
|
|
Evaporator temperature sensor (past)
|
Evaporator temperature sensor circuit is entered fail-safe mode at least once
|
Yes
|
|
12
|
|
Ambient temperature sensor (present)
|
Open/short circuit is in Ambient temperature sensor circuit
|
No
|
|
13
|
|
Ambient temperature sensor (past)
|
Ambient temperature sensor circuit is entered fail-safe mode at least once
|
Yes
|
|
14
|
|
Water temperature sensor (present)
|
Open/short circuit is in Water temperature sensor circuit
|
No
|
|
15
|
|
Water temperature sensor (past)
|
Water temperature sensor circuit is entered fail-safe mode at least once
|
Yes
|
|
18
|
|
Air mix actuator (potentiometer) (present)
|
Open/short circuit is in air mix actuator (potentiometer) circuit
|
No
|
|
19
|
|
Air mix actuator (potentiometer) (past)
|
Air mix actuator (potentiometer) circuit is entered fail-safe mode at least once
|
Yes
|
|
21
|
|
Airflow mode actuator (potentiometer) (present)
|
Open/short circuit is in airflow mode actuator (potentiometer) circuit
|
No
|
|
22
|
|
Airflow mode actuator (potentiometer) (past)
|
Airflow mode actuator (potentiometer) circuit is entered fail-safe mode at least once
|
Yes
|
|
58
|
|
Air mix actuator (motor lock) (past)
|
Air mix actuator circuit is entered fail-safe mode at least once
|
Yes
|
|
59
|
|
Airflow mode actuator (motor lock) (past)
|
Airflow mode actuator circuit is entered fail-safe mode at least once
|
Yes
|