LIFTGATE LOCK ACTUATOR INSPECTION


id0914z6804400

1. Disconnect the liftgate lock actuator connector.

2. Apply battery positive voltage to the liftgate lock actuator terminals and inspect the operation of the liftgate lock actuator.

• If not as specified, replace the liftgate lock.

Actuator operation

Connection

B+

GND

Lock
A
B
Unlock
B
A