TRUNK LID OPENER INSPECTION


id0914z6811400

1. Disconnect the trunk lid opener connector.

2. Apply battery positive voltage to the trunk lid opener terminals and inspect the trunk lid opener operation.

• If not as specified, replace the trunk lid opener.

Actuator operation

Connection

B+

GND

Open
B
C