THERMOSTAT INSPECTION [LF, L3]


id0112008013b5

1. Inspect the thermostat for the following.

• Closed valve in room temperature
• Opening temperature and lift of the valve
- If not as specified, replace the thermostat.
Thermostat initial-opening temperature
80-84 °C {176-183 °F}
Thermostat full-open temperature
97 °C {206 °F}
Thermostat full-open lift
8.0 mm {0.31 in} or more