THERMOSTAT INSPECTION [LF, L3]
id0112008013b5
1. Inspect the thermostat for the following.
-
• Closed valve in room temperature
-
• Opening temperature and lift of the valve
-
- If not as specified, replace the thermostat.
-
Thermostat initial-opening temperature
-
80-84 °C {176-183 °F}
-
Thermostat full-open temperature
-
97 °C {206 °F}
-
Thermostat full-open lift
-
8.0 mm {0.31 in} or more