1
|
INSPECT WIRING HARNESS BETWEEN ABS/TCS HU/CM AND DLC (DATA LINK CONNECTOR-2) FOR CONTINUITY AND SHORTS
Perform DTC inspection.
Is error message displayed regarding communication between ABS/TCS HU/CM and WDS or equivalent?
|
Yes
|
If a communication error message is displayed even after inspecting according to procedures displayed on WDS or equivalent, go to Step 8.
|
No
|
Go to next step.
|
2
|
CHECK FOR DTCS IN ABS/TCS HU/CM
Have DTCs been recorded in memory?
|
Yes
|
Perform inspection using appropriate DTC.
|
No
|
Go to next step.
|
3
|
INSPECT PID/DATA IN ABS/TCS HU/CM
Inspect the following items using WDS or equivalent PID/DATA monitor function.
• TRAC_SW (TCS OFF switch)
Is TRAC_SW ON displayed on WDS or equivalent?
|
Yes
|
Go to Step 6 (TCS OFF switch system malfunction).
|
No
|
Go to next step.
|
*4
|
CHECK FOR SHORT TO GROUND IN ABS/TCS HU/CM
Disconnect ABS/TCS HU/CM connector.
Does TCS OFF light go out with ignition switch on?
|
Yes
|
Replace ABS/TCS HU/CM (short to ground in ABS/TCS HU/CM).
|
No
|
Go to next step.
|
*5
|
INSPECT TCS OFF SWITCH
Disconnect TCS OFF switch connector.
Is TRAC_SW ON displayed on WDS or equivalent?
|
Yes
|
Go to next step.
|
No
|
Replace TCS OFF switch (TCS will not turn off, even though switch is OFF).
|
*6
|
VERIFY WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN ABS/TCS HU/CM AND TCS OFF SWITCH FOR SHORT TO GROUND) OR ABS/TCS HU/CM
Is there continuity between SST connector terminal P and ground?
|
Yes
|
Repair wiring harness between ABS/TCS HU/CM (terminal P) and TCS OFF switch.
|
*7
|
INSPECT WIRING HARNESS BETWEEN ABS/TCS HU/CM AND DLC (DATA LINK CONNECTOR-2) FOR CONTINUITY
Is there continuity between SST connector terminal X and data link connector?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between ABS/TCS HU/CM and data link connector.
|
*8
|
INSPECT WIRING HARNESS BETWEEN ABS/TCS HU/CM AND DLC (DATA LINK CONNECTOR-2) FOR SHORT TO B+
Is voltage approximately 12 V at SST connector terminal T?
|
Yes
|
Repair wiring harness between ABS/TCS HU/CM (terminal P) and data link connector.
|
No
|
Go to next step.
|
*9
|
INSPECT WIRING HARNESS BETWEEN ABS/TCS HU/CM AND DLC (DATA LINK CONNECTOR-2) FOR SHORT TO GROUND
Is there continuity between SST connector terminal T and ground?
|
Yes
|
Repair wiring harness between ABS/TCS HU/CM and data link connector.
|
No
|
Replace ABS/TCS HU/CM (communication circuit malfunction in ABS/TCS HU/CM).
|
|