DTC 11


id070200802600

DTC 11

Evaporator temperature sensor system inspection

POSSIBLE CAUSE

• Evaporator temperature sensor malfunction
• Climate control unit malfunction
• Open or short circuit between evaporator temperature sensor and climate control unit

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
• Inspect evaporator temperature sensor.
• Is it okay?
Yes
Go to next step.
No
Replace evaporator temperature sensor.
2
• Disconnect climate control unit connector (24-pin) and evaporator temperature sensor connector.
• Is there open circuit between following terminals of climate control unit connector (24-pin) and evaporator temperature sensor connector?
- 1Q-B
- 1I-A
Yes
Repair wiring harness.
No
Go to next step.
3
• Is there short circuit to ground between terminal 1Q of climate control unit connector (24-pin) and terminal B of evaporator temperature sensor connector?
Yes
Repair wiring harness.
No
Connect climate control unit connector, then go to next step.
4
• Turn ignition switch to ON position.
• Measure voltage at terminal 1Q of climate control unit connector (24-pin).
• Is voltage approximately 5 V?
Yes
This system is normal at present. (Erase the past failure from memory.)
No
Replace climate control unit.