STEP
|
INSPECTION
|
ACTION
|
1
|
INSPECT BLOWER 40 A FUSE
• Inspect BLOWER 40 A fuse.
• Is it okay?
|
Yes
|
Go to next step.
|
No
|
Replace fuse, then go to Step 15. If fuse burns out immediately, go to next step.
|
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE
• Turn ignition switch to ON position.
• Recirculate air inside vehicle.
• Does blower unit fan rotate smoothly?
|
Yes
|
Go to Step 4.
|
No
|
Go to next step.
|
3
|
INSPECT BLOWER UNIT INTAKE VENT
• Is intake vent of blower unit clogged?
|
Yes
|
Remove obstruction, then go to Step 15.
|
No
|
Inspect if there are any obstruction in passage between blower unit to A/C unit, then go to Step 15.
|
4*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER RELAY SYSTEM OR POWER MOS FET SYSTEM
• Turn ignition switch to ON position.
• Test voltage at the following terminal of blower motor.
-
- Terminal B (blower motor operation signal)
• Is voltage approximately 12 V?
|
Yes
|
Go to Step 8.
|
No
|
Go to next step.
|
5*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN FUSE BLOCK AND BLOWER RELAY) OR ELSEWHERE
• Test voltage at the following terminal of blower relay.
-
- Terminal A (IG2 signal)
-
- Terminal C (B+ signal)
• Is voltage approximately 12 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between blower relay and BLOWER 40 A fuse, then go to Step 15.
|
6*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND GROUND) OR ELSEWHERE
• Test voltage at the following terminal of blower relay.
-
- Terminal E (GND signal)
• Is voltage approximately 0 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between blower relay and ground, then go to Step 15.
|
7*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND BLOWER MOTOR) OR BLOWER RELAY
• Test voltage at the following terminal of blower relay.
-
- Terminal D (blower motor operation signal)
• Is voltage approximately 12 V?
|
Yes
|
Repair wiring harness between blower relay and blower motor, then go to Step 15.
|
No
|
Replace blower relay, then go to Step 15.
|
8*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER MOTOR OR ELSEWHERE
• Test voltage at the following terminal of blower motor.
-
- Terminal B (blower motor operation signal)
• Is voltage approximately 12 V?
|
Yes
|
Go to next step.
|
No
|
Inspect blower motor, then go to Step 15.
|
9*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER MOTOR AND POWER MOS FET) OR ELSEWHERE
• Test voltage at the following terminal of power MOS FET.
-
- Terminal C (blower motor operation signal)
• Is voltage approximately 12 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between blower motor and power MOS FET, then go to Step 15.
|
10*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN POWER MOS FET AND GROUND) OR ELSEWHERE
• Test voltage at the following terminal of power MOS FET.
-
- Terminal A (blower motor operation signal)
• Is voltage approximately 0 V?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between power MOS FET and ground, then go to Step 15.
|
11
|
INSPECT BLOWER UNIT
• Inspect fan in blower unit.
-
- Is fan free of interference with blower unit case?
-
- Is fan free of foreign material and obstruction?
• Is fan okay?
|
Yes
|
Go to next step.
|
No
|
Remove obstruction, repair or replace fan and blower unit case, then go to Step 15.
|
12*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POWER MOS FET OR ELSEWHERE
• Disconnect power MOS FET connector.
• Test voltage at the following terminal of power MOS FET.
-
- Terminal B (blower motor control signal)
• Is voltage approximately 10 V?
|
Yes
|
Replace power MOS FET, then go to Step 15.
|
No
|
Go to next step.
|
13*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN POWER MOS FET AND CLIMATE CONTROL UNIT) OR ELSEWHERE
• Turn ignition switch to LOCK position.
• Disconnect climate control unit connector.
• Inspect for continuity at the following terminals between power MOS FET and climate control unit.
-
- Terminal B-1C (24-pin, blower motor control signal)
-
- Terminal C-1A (24-pin, blower motor feedback signal)
• Is there continuity?
|
Yes
|
Go to next step.
|
No
|
Repair wiring harness between power MOS FET and climate control unit, then go to Step 15.
|
14*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (SHORT TO GROUND BETWEEN POWER MOS FET AND CLIMATE CONTROL UNIT)
• Inspect for continuity at the following terminal between power MOS FET and ground.
-
- Terminal B (blower motor control signal)-ground
• Is there continuity?
|
Yes
|
Repair wiring harness between power MOS FET and ground, then go to next step.
|
No
|
Replace climate control unit, then go to next step.
|
15
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Is air discharged from vent?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|