• When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while doing the inspection to discover whether poor contact points are the cause of any intermittent malfunction. If there is a problem, check to make sure connectors, terminals and wiring harness are connected correctly and undamaged.
STEP
|
INSPECTION
|
ACTION
|
|
---|---|---|---|
1
|
INSPECT OTHER WARNING AND INDICATOR LIGHTS CIRCUIT IN INSTRUMENT CLUSTER
• Turn ignition switch to ON position.
• Do other warning and indicator lights illuminate?
|
Yes
|
Turn ignition switch to LOCK position, then go to next step.
|
No
|
Inspect instrument cluster power supply system and ground system, then go to Step 5.
|
||
2
|
INSPECT SAS UNIT
• Turn ignition switch to LOCK position.
• Disconnect negative battery cable and wait for more than 1 minute.
• Remove column cover.
• Disconnect clock spring connector.
• Remove glove compartment.
• Disconnect passenger-side air bag module connector.
• Disconnect driver and passenger-side side air bag module connectors. (Vehicles with side air bag)
• Disconnect driver and passenger-side curtain air bag module connectors. (Vehicles with curtain air bag)
• Remove B-pillar lower trims. (Vehicle with pre-tensioner seat belt)
• Disconnect driver- and passenger-side pre-tensioner seat belt connectors. (Vehicle with pre-tensioner seat belt)
• Turn up floor covering.
• Disconnect all SAS unit connectors.
• Connect negative battery cable.
• Turn ignition switch to ON position.
• Does air bag system warning light illuminate?
|
Yes
|
Replace SAS unit, then go to Step 5.
|
No
|
Go to next step.
|
||
*3
|
INSPECT WIRING HARNESS BETWEEN SAS UNIT AND INSTRUMENT CLUSTER FOR SHORT TO GROUND
• Turn ignition switch to LOCK position.
• Disconnect negative battery cable.
• Disconnect instrument cluster connector.
• Is there continuity between terminal 1O of instrument cluster connector and ground?
|
Yes
|
Replace wiring harness, then go to Step 5.
|
No
|
Go to next step.
|
||
4
|
INSPECT INSTRUMENT CLUSTER
• Connect instrument cluster connector.
• Connect instrument cluster connector terminal 1O to ground, then reconnect
connector.
• Connect negative battery cable.
• Does air bag system warning light illuminate with ignition switch ON?
|
Yes
|
Replace instrument cluster, then go to next step.
|
No
|
Go to next step.
|
||
5
|
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
• Turn ignition switch to LOCK position.
• Disconnect negative battery cable and wait for more than 1 minute.
• Connect all SAS unit connectors.
• Connect driver and passenger-side
pre-tensioner seat belt connectors. (Vehicles with pre-tensioner seat belt)
• Connect driver and passenger-side curtain air bag module connectors. (Vehicles with curtain air bag)
• Connect driver and passenger-side side air bag module connectors. (Vehicles with side air bag)
• Connect passenger-side air bag module connector.
• Connect clock spring connector.
• Connect negative battery cable.
• Turn ignition switch to ON position.
• Does air bag system warning light operate properly?
|
Yes
|
Complete troubleshooting, then explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|