DTC 07:ER07


id0902f6818200

DTC 07:Er07

MD player

DETECTION CONDITION

Note
• When error occurs, error message "CHECK MD" is displayed in the LCD.
• Base unit detects MD reading error.

POSSIBLE CAUSE

• Defective MD (scratches or dirt)
• MD player malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT MD
• Inspect condition of MD where error has occurred.
• Is MD okay?
Yes
Go to next step.
No
Repair (remove foreign material) or replace MD, then go to next step.
2
INSPECT MD PLAYER
• Clear DTC.
• Insert and play MD for 12 seconds or more.
• Start on-board diagnostic test mode.
• Is DTC 07:Er07 displayed?
Yes
Replace MD player.
No
Troubleshooting completed.