INPUT/OUTPUT CHECK MODE FUNCTION


id092200996900

• The microcomputer built into instrument cluster detects the quality of input signal or individual part.
• Input/output check mode has both input circuit check and individual part check functions.

Input circuit check

• When the parts listed in the chart are operated and signal is output to the instrument cluster, the built-in microcomputer determines the operability of the input circuit based on that signal.

No.

Parts sending input signal

01
Buckle switch
04
Door switch
08
TNS relay
22
Fuel gauge sender unit
31
Key reminder switch

Individual circuit check

• By operating the parts listed in the chart, the built-in microcomputer determines the operability of the individual parts.

No.

Parts sending input signal

12
Speedometer
13
Tachometer
14
Buzzer
16
Fuel-level warning light
18
Ignition key illumination
23
Fuel gauge
25
Water temperature gauge
26
LCD