BLOWER MOTOR INSPECTION [FULL-AUTO AIR CONDITIONER]


id0740a1801000

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)(See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].)

2.  Remove the dashboard under cover. (See DASHBOARD UNDER COVER REMOVAL/INSTALLATION.)

3.  Remove the blower motor. (See BLOWER MOTOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)

4.  Connect battery positive voltage to blower motor terminal B, connect terminal A to ground, and then verify its operation.

am6zzw00015160

•  If there is any malfunction, replace the blower motor. (See BLOWER MOTOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)