PID/DATA MONITOR TABLE [HEADLIGHT AUTO LEVELING SYSTEM]


id0902i7960700

PID

Unit/Operation

Data contents

Module control terminal

H/L_BO_L
OK/NG
Displays the headlight LO (LH) open circuit detection status. (Detects during low beam on)
I
H/L_BO_R
OK/NG
Displays the headlight LO (RH) open circuit detection status. (Detects during low beam on)
Z
R_HGT_S
V
Displays voltage at auto leveling sensor
F, J, T
R_HGT_S_INI
V
Displays voltage at headlight auto leveling system initial setting
F, J, T
VPWR_IG
V
Displays auto leveling control module power supply voltage
A, C
VSPD
KPH, MPH
Displays vehicle speed
AB, AD