DTC DETECTION LOGIC AND CONDITIONS [SKYACTIV-G 2.0, SKYACTIV-G 2.5]
id0102h4100300
DTC No. |
Condition |
Detection condition |
---|---|---|
B10A2:00
|
Vehicle collision
|
• Collision signal from SAS control module is received.
|
P0010:00
|
Electric variable valve timing control circuit range/performance problem
|
• A malfunction is detected in the results of the on-board diagnostic test received from electric variable valve timing driver.
• The motor speed signal received from the electric variable valve timing driver is in error.
|
P0011:00
|
Electric variable valve timing control system: over-advanced
|
• For the advance amount from the maximum intake valve retard position, a condition in which the actual advance amount is larger than the target value continues for a specified period of time.
|
P0012:00
|
Electric variable valve timing control system: over-retarded
|
• For the advance amount from the maximum intake valve retard position, a condition in which the actual advance amount is smaller than the target value continues for a specified period of time.
|
P0014:00
|
Hydraulic variable valve timing control system: over-advanced
|
• For the advance amount from the maximum exhaust valve retard position, a condition in which the actual advance amount is larger than the target value continues for a specified period of time.
|
P0015:00
|
Hydraulic variable valve timing control system: over-retarded
|
• For the advance amount from the maximum exhaust valve retard position, a condition in which the actual advance amount is smaller than the target value continues for a specified period of time.
|
P0031:00
|
A/F sensor heater control circuit low input
|
• The PCM monitors the A/F sensor heater output voltage. If the PCM turns the A/F sensor heater off but the A/F sensor heater circuit remains low voltage, the PCM determines that the A/F sensor heater circuit has a malfunction.
|
P0032:00
|
A/F sensor heater control circuit high input
|
• The PCM monitors the A/F sensor heater output voltage. If the PCM turns the A/F sensor heater on but the A/F sensor heater circuit remains high voltage, the PCM determines that the A/F sensor heater circuit has a malfunction.
|
P0037:00
|
HO2S heater control circuit low input
|
• The PCM monitors the HO2S heater output voltage. If the PCM turns the HO2S heater off but the HO2S heater circuit remains low voltage, the PCM determines that the HO2S heater circuit has a malfunction.
|
P0038:00
|
HO2S heater control circuit high input
|
• The PCM monitors the HO2S heater output voltage. If the PCM turns the HO2S heater on but the HO2S heater circuit remains high voltage, the PCM determines that the HO2S heater circuit has a malfunction.
|
P0069:00
|
Manifold absolute pressure/atmospheric pressure correlation problem
|
• The PCM monitors difference between intake manifold vacuum and atmospheric pressure. If the difference is below −12 kPa {−0.12 kgf/cm2, −1.7 psi} or above 12 kPa {0.12 kgf/cm2, 1.7 psi} when the following conditions are met, the PCM determines that there is a MAP sensor performance problem.
MONITORING CONDITIONS
|
P0072:00*6
|
Ambient temperature sensor circuit low input
|
• The PCM monitors the input signal from the ambient temperature sensor. If the voltage from the ambient temperature sensor is below 0.2 V for 5 s, the PCM determines that the ambient temperature sensor circuit has a malfunction.
|
P0073:00*6
|
Ambient temperature sensor circuit high input
|
• The PCM monitors the input signal from the ambient temperature sensor. If the voltage from the ambient temperature sensor is above 4.8 V for 5 s, the PCM determines that the ambient temperature sensor circuit has a malfunction.
|
P0089:00
|
Spill valve control solenoid valve control circuit range/performance problem
|
• The average fuel pressure on the high pressure side, measured by the fuel pressure sensor while the camshaft is rotating at the specified speed, exceeds the specified value.
|
P0091:00
|
Fuel pressure regulator control circuit low input
|
• When the PCM turns the spill valve control solenoid valve off but the spill valve control solenoid valve control circuit voltage is low for 5 s, the PCM determines that the spill valve control solenoid valve control circuit has a malfunction.
MONITORING CONDITIONS
|
P0092:00
|
Fuel pressure regulator control circuit high input
|
• When the PCM turns the spill valve control solenoid valve on but the spill valve control solenoid valve circuit voltage is high for 5 s, the PCM determines that the spill valve control solenoid valve control circuit has a malfunction.
MONITORING CONDITIONS
|
P0097:00
|
IAT sensor No.2 circuit low input
|
• If the PCM detects that the IAT sensor No.2 voltage at the PCM terminal 1CE is 0.33 V or less for 5 s, the PCM determines that the IAT sensor No.2 circuit voltage is low.
|
P0098:00
|
IAT sensor No.2 circuit high input
|
• If the PCM detects that the IAT sensor No.2 voltage at the PCM terminal 1CE is 4.96 V or more for 5 s, the PCM determines that the IAT sensor No.2 circuit voltage is high.
|
P0101:00
|
MAF sensor circuit range/performance problem
|
• When the conditions are as follows, the PCM compares the intake airflow amount with the estimated intake airflow amount (calculated from the barometric pressure, MAP sensor and throttle opening angle).
MONITORING CONDITIONS
• The difference between the intake air amount measured by the MAF sensor and the estimated intake air amount estimated by the MAP sensor is outside of the specified value.
|
P0102:00
|
MAF sensor circuit low input
|
• The PCM monitors input voltage from the MAF sensor when the engine is running. If the input voltage at the PCM terminal 2BC is below 0.2 V for 5 s, the PCM determines that the MAF sensor circuit has a malfunction.
|
P0103:00
|
MAF sensor circuit high input
|
• The PCM monitors the input voltage from the MAF sensor when the engine is running. If the input voltage at the PCM terminal 2BC is above 4.94 V for 5 s, the PCM determines that the MAF sensor circuit has a malfunction.
|
P0107:00
|
MAP sensor circuit low input
|
• The PCM monitors the input voltage from the MAP sensor. If the input voltage at the PCM terminal 1BW is below 0.08 V for 5 s, the PCM determines that the MAP sensor circuit has a malfunction.
|
P0108:00
|
MAP sensor circuit high input
|
• The PCM monitors the input voltage from the MAP sensor. If the input voltage at the PCM terminal 1BW is above 4.89 V for 5 s, the PCM determines that the MAP sensor circuit has a malfunction.
|
P0112:00
|
IAT sensor No.1 circuit low input
|
• The PCM monitors the IAT sensor No.1 signal. If the PCM detects that the IAT sensor No.1 voltage at the PCM terminal 2U is below 0.19 V for 5 s, the PCM determines that the IAT sensor No.1 circuit has a malfunction.
|
P0113:00
|
IAT sensor No.1 circuit high input
|
• The PCM monitors the IAT sensor No.1 signal. If the PCM detects that the IAT sensor No.1 voltage at the PCM terminal 2U is above 4.62 V for 5 s, the PCM determines that the IAT sensor No.1 circuit has a malfunction.
|
P0116:00
|
ECT sensor circuit range/performance problem
|
• During the 5 min after the engine is started, the engine coolant temperature does not increase above 6 °C {11 °F}.
|
P0117:00
|
ECT sensor circuit low input
|
• The PCM monitors the ECT sensor signal. If the PCM detects that the ECT sensor voltage at the PCM terminal 1AK is below 0.2 V for 5 s, the PCM determines that the ECT sensor circuit has a malfunction.
|
P0118:00
|
ECT sensor circuit high input
|
• The PCM monitors the ECT sensor signal. If the PCM detects that the ECT sensor voltage at the PCM terminal 1AK is above 4.6 V for 5 s, the PCM determines that the ECT sensor circuit has a malfunction.
|
P0122:00
|
TP sensor No.1 circuit low input
|
• If the PCM detects that the TP sensor No.1 voltage at the PCM terminal 1BP is below 0.1 V while the engine is running, the PCM determines that the TP sensor No.1 circuit has a malfunction.
|
P0123:00
|
TP sensor No.1 circuit high input
|
• If the PCM detects that the TP sensor No.1 voltage at the PCM terminal 1BP is above 4.9 V after the ignition is switched to ON, the PCM determines that the TP sensor No.1 circuit has a malfunction.
|
P0130:00
|
Voltage problem between PCM terminal 1AB and PCM terminal 1AG
|
• A condition in which the voltage between PCM terminals 1AB and 1AG exceeds the specified range continues for the specified period or more.
|
P0131:00
|
A/F sensor circuit low input
|
• Any one of the following conditions is met:
|
P0132:00
|
A/F sensor circuit high input
|
• Any one of the following conditions is met:
|
P0133:00
|
A/F sensor circuit slow response
|
• The response speed of the A/F sensor input signal when the air/fuel ratio is fluctuated is slow.
|
P0134:00
|
A/F sensor circuit no activity detected
|
• The condition in which the A/F sensor element impedance is 403 Ω or more continues for 35 s.
|
P0137:00
|
HO2S circuit low input
|
• A condition in which the HO2S input voltage is less than the specified value continues for the specified period.
|
P0138:00
|
HO2S circuit high input
|
• A condition in which the HO2S input voltage exceeds the specified value continues for the specified period.
|
P013A:00
|
HO2S: Slow response (during transition from rich to lean)
|
• The response speed of the HO2S input signal when the air/fuel ratio is fluctuated from rich to lean is slow.
|
P0140:00
|
HO2S circuit no activity detected
|
• With the estimated temperature of the HO2S element exceeding the specified value, a condition in which the HO2S signal voltage is less than the specified value continues for the specified period.
|
P0171:00
|
Fuel trim system too lean
|
• Any one of the following conditions is met:
|
P0172:00
|
Fuel trim system too rich
|
• Any one of the following conditions is met:
|
P0191:00
|
Fuel pressure sensor circuit range/performance problem
|
• The difference between the actual and target fuel pressure is equal to or more than the specification, even though the fuel pressure feedback amount is maintained low or high.
|
P0192:00
|
Fuel pressure sensor circuit low input
|
• If the input voltage at the PCM terminal 1CA is less than 0.737 V for 5 s, the PCM determines that the fuel pressure sensor circuit is low.
|
P0193:00
|
Fuel pressure sensor circuit high input
|
• If the input voltage at the PCM terminal 1CA is more than 4.86 V for 5 s, the PCM determines that the fuel pressure sensor circuit is high.
|
P0201:00
|
Fuel injector circuit/open cylinder No.1
|
• If the fuel injection verification signal is not input at 25 times continuously even though the PCM drives the fuel injector No.1, the PCM determines that there is an open circuit in the fuel injector No.1 control circuit.
MONITORING CONDITIONS
|
P0202:00
|
Fuel injector circuit/open cylinder No.2
|
• If the fuel injection verification signal is not input at 25 times continuously even though the PCM drives the fuel injector No.2, the PCM determines that there is an open circuit in the fuel injector No.2 control circuit.
MONITORING CONDITIONS
|
P0203:00
|
Fuel injector circuit/open cylinder No.3
|
• If the fuel injection verification signal is not input at 25 times continuously even though the PCM drives the fuel injector No.3, the PCM determines that there is an open circuit in the fuel injector No.3 control circuit.
MONITORING CONDITIONS
|
P0204:00
|
Fuel injector circuit/open cylinder No.4
|
• If the fuel injection verification signal is not input at 25 times continuously even though the PCM drives the fuel injector No.4, the PCM determines that there is an open circuit in the fuel injector No.4 control circuit.
MONITORING CONDITIONS
|
P0222:00
|
TP sensor No.2 circuit low input
|
• If the PCM detects that the TP sensor No.2 voltage at the PCM terminal 1BU is below 0.1 V, the PCM determines that the TP sensor No.2 circuit has a malfunction.
|
P0223:00
|
TP sensor No.2 circuit high input
|
• If the PCM detects that the TP sensor No.2 voltage at the PCM terminal 1BU is above 4.9 V, the PCM determines that the TP sensor No.2 circuit has a malfunction.
|
P025B:00
|
Fuel pump control module circuit range/performance problem
|
• When any of the following conditions is met:
|
P025C:00
|
Fuel pump control module result of on-board diagnostic test low input
|
• Result of on-board test cannot be received from fuel pump control module (voltage is too low).
|
P025D:00
|
Fuel pump control module result of on-board diagnostic test high input
|
• Result of on-board test cannot be received from fuel pump control module (voltage is too high).
|
P0300:00
|
Random misfire detected
|
• Any one of the following conditions is met:
|
P0301:00
|
Cylinder No.1 misfire detected
|
• Any one of the following conditions is met:
|
P0302:00
|
Cylinder No.2 misfire detected
|
|
P0303:00
|
Cylinder No.3 misfire detected
|
|
P0304:00
|
Cylinder No.4 misfire detected
|
|
P0327:00
|
KS circuit low input
|
• The PCM monitors input signal from the KS. If the input voltage is below specified value for 5 s, the PCM determines that the KS circuit has a malfunction.
|
P0328:00
|
KS circuit high input
|
• The PCM monitors input signal from the KS. If the input voltage is above specified value for 5 s, the PCM determines that the KS circuit has a malfunction.
|
P0335:00
|
CKP sensor circuit problem
|
• There is no CKP sensor signal input while the exhaust camshaft rotates 5 times.
• CKP sensor input signal pattern, received while crankshaft rotates 10 times, is incorrect.
|
P0340:00
|
Intake CMP sensor circuit problem
|
• Intake CMP sensor input signal pattern, received while crankshaft rotates 24 times, is incorrect.
|
P0365:00
|
Exhaust CMP sensor circuit problem
|
• Exhaust CMP sensor input signal pattern, received while crankshaft rotates 24 times, is incorrect.
• Cylinder identification is not completed while the crankshaft rotates 13 times.
|
P0421:00
|
Catalytic converter system
|
• The PCM detects that the HO2S output fluctuates from lean to rich in a short amount of time at specified times continuously after recovery from fuel cut control.
|
P0443:00
|
Purge solenoid valve circuit problem
|
• The PCM monitors the purge solenoid valve control signal voltage and current. If the following conditions are met, the PCM determines that there is the purge solenoid valve control circuit problem.
|
P0461:00
|
Fuel gauge sender unit circuit range/performance problem
|
• The PCM monitors the fuel tank level difference before and after the PCM-calculated fuel consumption has reached more than 25 L {26 US qt, 22 Imp qt}. If the difference is less than 5 %, the PCM determines that there is a fuel gauge sender unit circuit range/performance problem.
|
P0462:00
|
Fuel gauge sender unit circuit low input
|
• The PCM monitors the fuel level signal and fuel gauge sender unit output voltage from the instrument cluster. If the PCM detects a fuel level or fuel gauge sender unit output voltage that is too low, the PCM determines that the fuel gauge sender unit circuit has a malfunction.
|
P0463:00
|
Fuel gauge sender unit circuit high input
|
• The PCM monitors the fuel level signal and fuel gauge sender unit output voltage from the instrument cluster. If the PCM detects a fuel level or fuel gauge sender unit output voltage that is too high, the PCM determines that the fuel gauge sender unit circuit has a malfunction.
|
P0480:00
|
Cooling fan relay No.1 control circuit malfunction
|
• The PCM monitors the cooling fan relay No.1 control signal voltage and current. If the following conditions are met, the PCM determines that there is the cooling fan relay No.1 control circuit problem.
|
P0482:00
|
Cooling fan relay No.2 and No.3 control circuit malfunction
|
• The PCM monitors the cooling fan relay No.2 and No.3 control signal voltage and current. If the following conditions are met, the PCM determines that there is the cooling fan relay No.2 and No.3 control circuit problem.
|
P0500:00
|
VSS circuit problem
|
• If an error in the wheel speed signal from the DSC HU/CM is detected by CAN when the following conditions are met:
|
P0506:00
|
IAC system RPM lower than expected
|
• The actual idle speed is lower than expected by 100 rpm for 14 s, when the brake pedal is depressed (brake switch is on).
|
P0507:00
|
IAC system RPM higher than expected
|
• The actual idle speed is higher than expected by 200 rpm for 14 s, when the brake pedal is depressed (brake switch is on).
|
P0520:00
|
Oil pressure switch circuit problem
|
• The oil pressure switch is off for a continuous 5 s even though the engine is stopped.
|
P0524:00
|
Engine oil pressure too low
|
• The oil pressure switch is on for a continuous 5 s with the following condition met: (engine oil pressure warning light illuminates when 1 s has elapsed)
|
P0532:00*6
|
Refrigerant pressure sensor circuit low input
|
• The PCM monitors input voltage from the refrigerant pressure sensor when the ignition switch is ON. If the input voltage at the PCM terminal 2AX is below 0.1 V for 5 s, the PCM determines that the refrigerant pressure sensor circuit has a malfunction.
|
P0533:00*6
|
Refrigerant pressure sensor circuit high input
|
• The PCM monitors the input voltage from the refrigerant pressure sensor when the ignition switch is ON. If the input voltage at the PCM terminal 2AX is above 4.9 V for 5 s, the PCM determines that the refrigerant pressure sensor circuit has a malfunction.
|
P0555:00*5
|
Power brake unit vacuum sensor circuit problem
|
• The PCM monitors the power brake unit vacuum sensor signal voltage while the ignition switch is ON. If the PCM detects the power brake unit vacuum sensor voltage is below 0.15 V or above 4.8 V for 5 s, the PCM determines that the power brake unit vacuum sensor circuit has problem.
|
P0571:00
|
Brake switch circuit problem
|
• The PCM monitors changes in input voltage for brake switch No.1 and No.2.
• The brake switch circuit malfunction is determined when the following 2 conditions are repeated 5 times or more when vehicle speed is 10 km/h {6.2 mph} or more.
|
P057F:00*5
|
Power system: Battery deterioration
|
• The battery charge/discharge flow exceeds the specification.
|
P058A:00*5
|
Current sensor: Function malfunction
|
• Error signal from the current sensor is received.
|
P0600:00
|
Serial communication link
|
• PCM internal malfunction.
|
P0601:00
|
PCM memory check sum error
|
• PCM internal memory check sum error.
|
P0602:00
|
PCM programming error
|
• No configuration data in the PCM.
|
P0604:00
|
PCM RAM error
|
• PCM internal RAM malfunction.
|
P0606:00
|
PCM processor error
|
• PCM internal CPU malfunction.
|
P0607:00
|
Control module performance problem
|
• PCM internal malfunction.
|
P0610:00
|
PCM vehicle configuration error
|
• PCM data configuration error.
|
P0615:00*5
|
Starter relay circuit problem
|
• The PCM records DTCs when the number of times the engine has been started reaches the warrantied performance frequency for the starter or starter relay (180,000 times).
|
P061B:00
|
Internal control module torque calculation performance problem
|
• Indicates that a calculation error occurred in the PCM.
• There is a malfunction in the sensor input signal to the PCM.
|
P061D:00
|
Internal control module engine air mass performance problem
|
• Indicates an error occurred in the PCM.
|
P061F:00
|
Internal control module throttle valve actuator controller performance problem
|
• When any of the following conditions is met:
|
P0628:00
|
Fuel pump control module circuit low input
|
• When the PCM outputs a duty signal to the fuel pump control module, the difference in voltage between fuel pump unit terminals B and D is less than 1.5 V for a continuous 5 s.
|
P0629:00
|
Fuel pump control module circuit high input
|
• Over-current is detected.
|
P0638:00
|
Throttle valve actuator control range/performance problem
|
• The PCM compares the actual TP with the target TP. If the difference is more than the threshold value, the PCM determines that there is a throttle valve actuator control range/performance problem.
|
P064D:00
|
Internal control module A/F sensor processor performance problem
|
• Malfunction in A/F sensor signal circuit in PCM occurs.
|
P0685:00
|
Main relay control circuit open
|
• The period of time in which the PCM power supply remains on after the ignition is switched off is not within the specified time.
|
P06B8:00
|
Internal control module non-volatile RAM error
|
• PCM internal EEPROM malfunction.
|
P06DA:00
|
Engine oil solenoid valve circuit problem
|
• The engine oil solenoid valve control current exceeds the specification or the control voltage at the PCM terminal 1AS is less than the specification relative to the PCM control condition.
|
P0703:00
|
Brake switch input circuit problem
|
• The PCM monitors the input signal from the brake switch No.1. If the input signal does not change while following decelerating 8 times, the PCM determines that there is a brake switch No.1 input circuit problem.
MONITORING CONDITIONS
|
P0704:00*2
|
CPP switch input circuit problem
|
• The PCM monitors changes in input voltage from the CPP switch. If the PCM does not detect a voltage change while the vehicle runs with vehicle speed above 30 km/h {19 mph} and stops 8 times alternately, the PCM determines that the CPP switch circuit has a malfunction.
|
P07BE:00*7
|
Transmission indeterminate failure (failed to neutral)
|
• Correlation malfunction between neutral switches No.1 and No.2.
|
P0850:00*2
|
Neutral switch No.1 input circuit problem
|
• The PCM monitors changes in input voltage from the neutral switch No.1. If the PCM does not detect a voltage change while driving the vehicle at a vehicle speed above 30 km/h {19 mph}and clutch pedal is pressed and released 10 times repeatedly, the PCM determines that the neutral switch No.1 circuit has a malfunction.
|
P0A0F:00*5
|
Engine failed to restart
|
• Any of following conditions occurs:
|
P0A12:00*4
|
DC-DC converter (i-ELOOP): low input/output
|
• Internal malfunction signal from DC-DC converter via front body control module (FBCM) is received.(CAN/LIN communication).
• Input signal from the DC-DC converter limits the pressure increase time.
• Input signal from the DC-DC converter does not implement pressure increase after a pressure increase command to the DC-DC converter.
|
P0A8D:00*5
|
Power supply system circuit low input
|
• Any one of the following conditions is met:
|
P0A8F:00*5
|
Power system: Low input
|
• Any one of the following conditions is met:
|
P0A94:00*5
|
DC-DC converter: control circuit signal error (Without i-ELOOP)
DC-DC converter (i-ELOOP): control circuit signal error (With i-ELOOP)
|
• Internal malfunction signal from DC-DC converter via front body control module (FBCM) is received.(CAN/LIN communication).
• Input signal from the DC-DC converter limits the pressure increase time.
• Input signal from the DC-DC converter does not implement pressure increase after a pressure increase command to the DC-DC converter.
|
P111A:00
|
Engine coolant temperature is high
|
• The engine coolant temperature is 122 °C {252 °F} or more.
|
P117A:00
|
Engine oil temperature is high
|
• With the transmission in 5th gear or lower gear, an engine speed of 6,100 rpm (SKYACTIV-G 2.0)/5,800 rpm (SKYACTIV-G 2.5) continues for 6 min.
|
P1260:00
|
Immobilizer system problem
|
• The start stop unit detects an immobilizer system malfunction.
|
P1380:00
|
Electric variable valve timing control circuit problem
|
• A malfunction is detected in the results of the on-board diagnostic test received from electric variable valve timing driver.
|
P151B:00*1
|
IAC system problem
|
• The PCM cannot control the idle speed toward the target idle speed during the KOER self test.
|
P176E:00*7
|
Clutch stroke sensor/Starter interlock switch correlation problem
|
• Correlation malfunction between clutch stroke sensor and starter interlock switch.
|
P1794:00*4
|
Capacitor (i-ELOOP) system: Capacitor (i-ELOOP) malfunction
|
• Any one of the following conditions is met:
|
P2090:00
|
OCV circuit low input
|
• The PCM monitors the OCV voltage. If the PCM detects the OCV control voltage (calculated from the OCV) is below the specification voltage (calculated from the battery positive voltage), the PCM determines that the OCV circuit has a malfunction.
|
P2091:00
|
OCV circuit high input
|
• The PCM monitors the OCV current. If the PCM detects that the OCV control current (calculated from the OCV) is above the specification current, the PCM determines that the OCV circuit has a malfunction.
|
P2096:00
|
HO2S fuel injection control system: Air fuel too lean
|
• Depending on the correction deviation of the A/F sensor, a condition in which the fuel feedback correction amount (SHRTFT12) for the HO2S is the specified value (2 %) or more and the fuel learning correction amount (SHRTFT12+LONGFT12) is the specified value (2.5 %) or more continues for a period of 25 s.
|
P2097:00
|
HO2S fuel injection control system: Air fuel too rich
|
• Depending on the correction deviation of the A/F sensor, a condition in which the fuel feedback correction amount (SHRTFT12) for the HO2S is the specified value (−2 %) or less and the fuel learning correction amount (SHRTFT12+LONGFT12) is the specified value (−2.5 %) or less continues for a period of 25 s.
|
P2101:00
|
Throttle valve actuator control motor circuit range/performance problem
|
• The PCM turns the main relay on, but if the input voltage is 6.0 V or less, then the PCM determines that the main relay control circuit voltage is low.
• There is a system error in the electrical throttle control system of the PCM.
|
P2107:00
|
Throttle valve actuator control module processor error
|
• Throttle valve actuator control module internal processor error.
|
P2109:00
|
TP sensor minimum stop range/performance problem
|
• If the fully-close throttle position is 5.1 ° or lower, or 15.9 ° or more (even though the fully-close throttle position learning is finished), the PCM determines there is a malfunction.
|
P2110:00
|
Throttle valve actuator control system-forced limited RPM
|
• The throttle valve actuator control system is in the failure mode effects management mode.
|
P2112:00
|
Throttle valve actuator motor current range/performance problem
|
• If the duty ratio is 95 % or more, the PCM determines that there is a throttle valve actuator control system range/performance problem.
|
P2119:00
|
Throttle valve actuator control throttle body range/performance problem
|
• The PCM compares the actual TP with initial setting TP when the ignition is switched to off. If the TP is higher than the initial setting TP, the PCM determines that there is a throttle valve return spring malfunction.
|
P2122:00
|
APP sensor No.1 circuit low input
|
• The PCM monitors the input voltage from APP sensor No.1 when the engine is running. If the input voltage at the PCM terminal 2AN is less than 0.1 V, the PCM determines that the APP sensor No.1 circuit input voltage is low.
|
P2123:00
|
APP sensor No.1 circuit high input
|
• The PCM monitors the input voltage from APP sensor No.1 when the engine is running. If the input voltage at the PCM terminal 2AN is above 4.9 V, the PCM determines that the APP sensor No.1 circuit input voltage is high.
|
P2127:00
|
APP sensor No.2 circuit low input
|
• The PCM monitors the input voltage from APP sensor No.2 when the engine is running. If the input voltage at the PCM terminal 2AS is less than 0.1 V, the PCM determines that the APP sensor No.2 circuit has a malfunction.
|
P2128:00
|
APP sensor No.2 circuit high input
|
• The PCM monitors the input voltage from APP sensor No.2 when the engine is running. If the input voltage at the PCM terminal 2AS is more than 4.9 V, the PCM determines that the APP sensor No.2 circuit has a malfunction.
|
P2135:00
|
TP sensor No.1/No.2 voltage correlation problem
|
• The PCM compares the input voltage from TP sensor No.1 with the input voltage from TP sensor No.2. If the difference is more than the specification, the PCM determines that there is a TP sensor No.1/No.2 voltage correlation problem.
|
P2138:00
|
APP sensor No.1/No.2 voltage correlation problem
|
• The PCM compares the input voltage from APP sensor No.1 with the input voltage from APP sensor No.2 when the engine is running. If the difference is more than the specification, the PCM determines that there is an APP sensor No.1/No.2 angle correlation problem.
|
P2199:00
|
IAT sensor No.2 correlation problem
|
• IAT sensor No.1 and IAT sensor No.2 are compared and correlation error occurs.
|
P2228:00
|
BARO sensor circuit low input
|
• The PCM monitors input voltage from the BARO sensor. If the input voltage is below specified value for 5 s, the PCM determines that the BARO sensor circuit has a malfunction.
|
P2229:00
|
BARO sensor circuit high input
|
• The PCM monitors input voltage from the BARO sensor. If the input voltage is above specified value for 5 s, the PCM determines that the BARO sensor circuit has a malfunction.
|
P2237:00
|
Open circuit between A/F sensor terminal B and PCM terminal 1AG
|
• After A/F sensor activation, a condition in which PCM terminal 1AB voltage is within the specified range continues for the specified period or longer.
|
P2243:00
|
A/F sensor reference voltage circuit open
|
• A condition in which the PCM terminal 1W voltage is the specified value or more continues for 30 s.
|
P2251:00
|
Open circuit between A/F sensor terminal D and PCM terminal 1AB
|
• The following conditions are met:
|
P2299:00
|
Accelerator pedal: spring back malfunction
|
• Brake override system operates.
|
P2302:00
|
Ion sensor No.1 circuit problem
|
• After the engine is started, when the engine speed is 2,000 rpm or less, the signal input to the PCM from ion sensor No.1 is in error.
|
P2305:00
|
Ion sensor No.2 circuit problem
|
• After the engine is started, when the engine speed is 2,000 rpm or less, the signal input to the PCM from ion sensor No.2 is in error.
|
P2308:00
|
Ion sensor No.3 circuit problem
|
• After the engine is started, when the engine speed is 2,000 rpm or less, the signal input to the PCM from ion sensor No.3 is in error.
|
P2311:00
|
Ion sensor No.4 circuit problem
|
• After the engine is started, when the engine speed is 2,000 rpm or less, the signal input to the PCM from ion sensor No.4 is in error.
|
P2502:00
|
Generator system: Malfunction in voltage generated by generator
|
• The voltage generated by the generator is 17 V or higher and the battery voltage is 11 V or less for a continuous specified time.
|
P2503:00
|
Generator system: Voltage generated by generator is low
|
• A condition continues for a specified period of time in which the target generator output current calculated by the PCM is 20A or more and the generator output voltage is 8.5 V or less.
|
P2504:00
|
Generator system: Voltage generated by generator is high
|
• The voltage generated by the generator is 18.5 V or higher or the battery voltage is 16 V or higher for a continuous specified time.
|
P2507:00
|
PCM battery voltage low input
|
• The PCM monitors the voltage of backup battery positive terminal. If the PCM detects that the battery positive terminal voltage is below 6 V for 5 s, the PCM determines that the backup voltage circuit has a malfunction.
|
P253F:00
|
Engine oil malfunction
|
• Traveled distance or number of days used exceeds the specification
|
P2610:00
|
Instrument cluster internal engine off timer performance problem
|
• Instrument cluster internal engine off timer is damaged.
|
U0073:00
|
CAN system communication error (HS CAN)
|
• Malfunction in CAN bus communication line.
|
U0074:00*3
|
CAN system communication error (local CAN between PCM and TCM)
|
• Malfunction in CAN bus communication line.
|
U0101:00*3
|
CAN communication: communication error to TCM
|
• Communication error between the PCM and TCM continues for 5 s or more.
|
U0104:00*8
|
CAN communication: communication error to vehicle control module (V/C-module)
|
• Communication error between the PCM and vehicle control module (V/C-module) continues for 5 s or more.
|
U0121:00
|
CAN communication: communication error to DSC HU/CM
|
• Communication error between the PCM and DSC HU/CM continues for 5 s or more.
|
U0131:00
|
CAN communication: communication error to EPS control module
|
• Communication error between the PCM and EPS control module continues for 5 s or more.
|
U0140:00
|
CAN communication: communication error to front body control module (FBCM)
|
• Communication error between the PCM and front body control module (FBCM) continues for 5 s or more.
|
U0151:00
|
CAN communication: communication error to SAS control module
|
• Communication error between the PCM and SAS control module continues for 5 s or more.
|
U0155:00
|
CAN communication: communication error to instrument cluster
|
• Communication error between the PCM and instrument cluster continues for 5 s or more.
|
U0214:00
|
CAN communication: communication error to start stop unit
|
• Communication error between the PCM and start stop unit continues for 5 s or more.
|
U0235:00
|
CAN communication: communication error to laser sensor
|
• Communication error between the PCM and laser sensor continues for 5 s or more.
|
U0298:00
|
• CAN/LIN communication system: DC-DC converter information communication error with front body control module (FBCM) (without i-ELOOP)
• CAN communication: communication error to DC-DC converter (i-ELOOP) (with i-ELOOP)
|
Without i-ELOOP
• PCM detects a DC-DC converter information communication error from front body control module (FBCM).
With i-ELOOP
• PCM detects a communication error between the PCM and DC-DC converter (i-ELOOP).
|
U0302:00*3
|
TCM processor error
|
• When any of the following conditions is met:
|
U0305:00*8
|
Vehicle control module (V/C-module) error
|
• When any of the following conditions is met:
|
U0315:00
|
DSC HU/CM error
|
• When any of the following conditions is met:
|
U0320:00
|
EPS control module error
|
• When any of the following conditions is met:
|
U0323:00
|
Instrument cluster error
|
• When any of the following conditions is met:
|
U0336:00
|
SAS control module error
|
• When any of the following conditions is met:
|
U0338:00
|
Start stop unit error
|
• When any of the following conditions is met:
|
U0433:00
|
Abnormal message from rear body control module (RBCM)
|
• Correct data cannot be received from rear body control module (RBCM).
|
U1007:00*5
|
CAN/LIN communication system: current sensor information communication error with front body control module (FBCM)
|
• PCM detects a current sensor information communication error from front body control module (FBCM).
|
U2300:00
|
Global central configuration error
|
• Any of following conditions occurs:
|