UP SWITCH INSPECTION [GW6A-EL]


id0517i1600500


Continuity Inspection

Note
•  The up switch is built into the selector lever component.

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)

2.  Remove the front console. (See FRONT CONSOLE REMOVAL/INSTALLATION.)

3.  Disconnect the selector lever component connector.

am6zzw00009000

4.  Verify that the continuity between selector lever component terminals C and J.

ac5wzw00000787

•  If not as verified, replace the selector lever component. (See AUTOMATIC TRANSAXLE SHIFT MECHANISM REMOVAL/INSTALLATION.)

Up switch specification

Test condition

Continuity

Selector lever is in the M position (+) side position.
Continuity
Selector lever is not in the M position (+) side position.
No continuity