NO.2 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [FULL-AUTO AIR CONDITIONER]
id0703c1800500
2
|
Amount of air blown from vents does not change.
|
DESCRIPTION
|
• Malfunction in blower system
|
POSSIBLE CAUSE
|
• Blower unit malfunction
• Blower motor malfunction
• Malfunction in blower fan controller system
• Climate control unit malfunction
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT HEATER 40 A FUSE
• Inspect the HEATER 40 A fuse.
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
If the fuse is melted:
Repair or replace wiring harness for short to ground and replace the fuse.
If the fuse is deterioration:
Replace the fuse.
Then go to Step 15.
|
||
2
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE
• Switch the ignition ON (engine off or on).
• Turn the airflow volume control dial clockwise.
• Recirculate air inside the vehicle.
• Does the blower motor rotate smoothly?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 4.
|
||
3
|
INSPECT BLOWER UNIT INTAKE VENT
• Is blower unit intake vent clogged?
|
Yes
|
Remove obstruction, then go to Step 15.
|
No
|
Inspect if there are any obstruction in the A/C unit passage, then go to Step 15.
|
||
4*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER RELAY SYSTEM OR BLOWER FAN CONTROLLER SYSTEM
• Switch the ignition ON (engine off or on).
• Turn the airflow volume control dial clockwise.
• Measure the voltage at the following blower motor terminal.
• Is voltage approx. 12 V?
|
Yes
|
Go to Step 8.
|
No
|
Go to the next step.
|
||
5*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN FUSE BLOCK AND BLOWER RELAY) OR ELSEWHERE
• Measure the voltage at the following blower relay terminals.
• Is the voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between blower relay terminal and HEATER 40 A fuse.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 15.
|
||
6*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND GROUND) OR ELSEWHERE
• Measure the voltage at the following blower relay terminal.
• Is the voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between blower relay terminal and front body control module (FBCM) terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 15.
|
||
7*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND BLOWER FAN CONTROLLER) OR BLOWER RELAY
• Measure the voltage at the following blower relay terminal.
• Is the voltage approx. 12 V?
|
Yes
|
Repair the wiring harness for lack of continuity between the blower relay and blower fan controller, then go to Step 15.
|
No
|
Replace the blower relay, then go to Step 15.
|
||
8*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER MOTOR OR ELSEWHERE
• Measure the voltage at the following blower motor terminal.
• Is the voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Inspect the blower motor, then go to Step 15.
|
||
9*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER MOTOR AND BLOWER FAN CONTROLLER) OR ELSEWHERE
• Measure the voltage at the following terminal of blower fan controller.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between blower motor terminal and blower fan controller terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 15.
|
||
10*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER FAN CONTROLLER AND GROUND) OR ELSEWHERE
• Measure the voltage at the following blower fan controller terminal.
• Is the voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between blower fan controller terminal and ground.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 15.
|
||
11
|
INSPECT BLOWER UNIT
• Inspect the fan in blower unit.
• Is the fan normal?
|
Yes
|
Go to the next step.
|
No
|
Remove obstruction, repair or replace the fan and A/C unit case, then go to Step 15.
|
||
12*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN BLOWER FAN CONTROLLER OR ELSEWHERE
• Disconnect blower fan controller connector.
• Turn the fun switch to 1st position from off.
• Measure the voltage at the following blower fan controller terminal.
• Is voltage approx. 7 V?
|
Yes
|
Replace the blower fan controller, then go to Step 15.
|
No
|
Go to the next step.
|
||
13*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER FAN CONTROLLER AND CLIMATE CONTROL UNIT) OR ELSEWHERE
• Switch the ignition off.
• Disconnect climate control unit connector.
• Inspect for continuity at the following terminals between the blower fan controller and climate control unit.
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between blower fan controller terminal and climate control unit terminal.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness.
Go to Step 15.
|
||
14*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR WIRING HARNESS (SHORT TO GROUND IN WIRING HARNESS BETWEEN BLOWER FAN CONTROLLER AND CLIMATE CONTROL UNIT)
• Inspect for continuity at the following terminal between the blower fan controller and ground.
• Is there continuity?
|
Yes
|
If there is a common connector:If there is no common connector:
Refer to the wiring diagram and verify whether or not there is a common connector between blower fan controller terminal and ground.
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
• Repair or replace the malfunctioning part.
• Repair or replace the wiring harness which has a short to ground.
Go to the next step.
|
No
|
Replace the climate control unit, then go to the next step.
|
||
15
|
CONFIRM THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Is air discharged from vent?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|