DOOR GLASS DOES NOT OPERATE USING THE REQUEST SWITCH [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]
id090361884200
Description
Possible cause
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
DETERMINE IF MALFUNCTION CAUSE IS DOOR LOCK
• Inspect the door lock/unlock operation using the request switch.
• Does it operate normally?
|
Yes
|
Go to the next step.
|
No
|
Refer to "Advanced keyless entry system does not operate" malfunction diagnosis and perform the inspection.
|
||
2
|
INSPECT IF MALFUNCTION CAUSE IS SHORT TO GROUND IN WIRING HARNESS BETWEEN POWER WINDOW MAIN SWITCH AND REAR BODY CONTROL MODULE (RBCM)
• Disconnect the negative battery cable.
• Disconnect the rear body control module (RBCM)
• Inspect for continuity between the following wiring harness terminals (vehicle wiring harness side) and body ground.
• Is there continuity?
|
Yes
|
• Repair or replace the wiring harness which is shorted to ground.
• After repair procedure, go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT IF MALFUNCTION CAUSE IS SHORT TO POWER SUPPLY IN WIRING HARNESS BETWEEN POWER WINDOW MAIN SWITCH AND REAR BODY CONTROL MODULE (RBCM)
• Verify that the rear body control module (RBCM)
• Connect the negative battery cable.
• Measure the voltage at the following terminals (vehicle wiring harness).
• Is there continuity?
|
Yes
|
• Repair or replace the wiring harness which is shorted to power supply.
• After repair procedure, go to Step 5.
|
No
|
Go to the next step.
|
||
4
|
INSPECT IF MALFUNCTION CAUSE IS OPEN CIRCUIT IN WIRING HARNESS BETWEEN POWER WINDOW MAIN SWITCH AND REAR BODY CONTROL MODULE (RBCM)
• Disconnect the negative battery cable.
• Disconnect the power window main switch
• Inspect for continuity between the following terminals (vehicle wiring harness).
• Is there continuity?
|
Yes
|
• Replace the power window main switch
• After repair, go to the next step.
|
No
|
• Repair or replace the wiring harness for an open circuit.
• After repair, go to the next step.
|
||
5
|
VERIFY IF MALFUNCTION CAUSE WAS CORRECTED
• Does the exterior open/close function operate using the request switch?
|
Yes
|
Troubleshooting completed. (Explain the contents of the servicing to the customer.)
|
No
|
If the malfunction has not been resolved, repeat the inspection from Step 1.
|