DOOR GLASS STOPS BEFORE FULLY OPENING/CLOSING [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]


id090361884400


Description

•  Door glass stops before fully opening/closing

Possible cause

•  Power window main switch malfunction
•  Power window subswitch malfunction
•  Power window motor malfunction
•  Battery malfunction (Low voltage)
•  Door glass improper installation
•  Power window initialization procedure error
•  Start stop unit malfunction
•  Rear body control module (RBCM) malfunction
•  LF control unit malfunction
•  Keyless receiver malfunction
•  Advanced keyless entry system signal reception error (outside operation area, radio signal interference)

Diagnostic Procedure

Step

Inspection

Action

1
•  Operate the door glass in auto/manual by operating the power window main switch/power window subswitch.
•  Does the door glass stop before fully opening/closing using either operation?
Yes
Inspect the following parts, and repair or replace.
•  Power window main switch
•  Power window subswitch
•  Power window motor
•  Battery (Low voltage)
•  Door glass (Installation condition)
No
Go to the next step.
2
•  Inspect the operation of the door glass by repeating Step 1 above.
•  Does the door glass stop before fully opening/closing while in auto operation?
Yes
Perform the power window initialization procedure.
No
Go to the next step.
3
•  Open the door glass by operating the transmitter.
•  Does the door glass stop before fully opening?
Yes
Inspect the following parts, and repair or replace.
•  Keyless receiver
•  LF control unit
•  Start stop unit
•  Rear body control module (RBCM)
•  Advanced keyless entry system signal reception (the system is in outside operation area and/or influenced radio signal interference intermittently)
No
Go to the next step.
4
•  Close the door glass by operating the transmitter.
•  Does the door glass stop before fully closing?
Yes
Inspect the following parts, and repair or replace.
•  Keyless receiver
•  LF control unit
•  Start stop unit
•  Rear body control module (RBCM)
•  Advanced keyless entry system signal reception (the system is in outside operation area and/or influenced radio signal interference intermittently)
No
Reinspect for malfunction recurrence. If the malfunction is not corrected, repeat the procedure from Step 1.