SLIDE MOTOR INSPECTION
id091300800900
LH
1. Disconnect the negative battery cable and wait for 1 min or more. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)
2. Disconnect the slide motor connector.
3. Apply battery positive voltage to the slide motor terminals and inspect the front seat operation.
am6zzw00017993
|
Front seat operation |
Connection |
|
---|---|---|
B |
D |
|
Forward
|
GND
|
B+
|
Backward
|
B+
|
GND
|
RH
1. Disconnect the negative battery cable and wait for 1 min or more. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)
2. Disconnect the slide motor connector.
3. Apply battery positive voltage to the slide motor terminals and inspect the front seat operation.
am6zzw00017994
|
Front seat operation |
Connection |
|
---|---|---|
B |
D |
|
Forward
|
B+
|
GND
|
Backward
|
GND
|
B+
|