HBC INDICATOR LIGHT (GREEN)/HBC WARNING LIGHT (AMBER)
id091800005200
Purpose
HBC indicator light (green)
HBC warning light (amber)
Function
HBC indicator light (green)
HBC warning light (amber)
am6zzn00002335
|
Construction
am6zzn00002336
|
Operation
HBC indicator light (green)
1. The instrument cluster receives the system conditions display request signal from the forward sensing camera (FSC) via the CAN signal.
2. The instrument cluster turns the transistor on based on the system conditions display request signal.
3. When the transistor turns on, a ground circuit with the HBC indicator light (green) is established, and the HBC indicator light (green) illuminates.
am6zzn00002337
|
HBC warning light (amber)
1. The instrument cluster receives the system conditions display request signal from the forward sensing camera (FSC) or a system malfunction display request signal via a CAN signal.
2. The instrument cluster turns the transistor on intermittently for a system malfunction display request signal, and continuously for a system conditions display request signal.
3. When the transistor is turned on intermittently, the HBC warning light (amber) flashes, and when it is turned on continuously, the HBC indicator light (green) illuminates.
am6zzn00002338
|
Fail-safe