STAY DAMPER DISPOSAL
id091100521000
1. Wear protective eye wear.
2. Position the stay damper horizontally.
am6zzw00009455
|
3. Drain gas and oil by cutting the position indicated in the figure to a 2—3 mm {0.08—0.11 in} depth using a metal saw.
4. Verify that the gas and oil is drained completely by pulling and pushing the piston rod several times with the cut position facing downward.
am2zzw00000435
|
5. Cut off the bottom of the stay damper.
am3uuw00007988
|
6. Dispose of the stay damper.