OIL PUMP INSPECTION [MZR-CD 2.2]


id0110f2505300


Rotor Clearance

1.  Measure the following clearances.

(1)  Measure the tip clearance between the inner rotor and the outer rotor using a feeler gauge.
•  If it exceeds the maximum specification, replace the inner rotor or the outer rotor, or the both.
am6zzw00004439
Standard tooth tip clearance between inner rotor and outer rotor
0.04—0.18 mm {0.002—0.007 in}
Maximum tooth tip clearance between inner rotor and outer rotor
0.22 mm {0.0087 in}
(2)  Measure the body clearance between the outer rotor and the oil pump body using a feeler gauge.
•  If it exceeds the maximum specification, replace the outer rotor or oil pump body, or both.
am6zzw00004440
Standard body clearance between outer rotor and oil pump body
0.10—0.19 mm {0.0040—0.0074 in}
Maximum body clearance between outer rotor and oil pump body
0.25 mm {0.0098 in}
(3)  Measure the side clearance using a straight edge and a feeler gauge.
•  If it exceeds the maximum specification, replace the inner rotor or oil pump body, or the both.
am6zzw00004441
Oil pump standard side clearance
0.04—0.10 mm {0.002—0.003 in}
Oil pump maximum side clearance
0.15 mm {0.0059 in}