VARIABLE BOOST CONTROL (VBC) SOLENOID VALVE CONSTRUCTION/OPERATION [MZR-CD 2.2]
id0113f3151000
Construction
• Consists of the solenoid coil, spring, and plunger.
Operation
Energized
• The solenoid coil magnetizes, pulling the plunger. The passage between B and C ports opens due to the plunger being pulled, and vacuum is applied to the actuator.
Non-energized
• The vacuum passage is blocked, and the passage between ports A and B opens, depressurizing the actuator.