ENGINE COOLANT TEMPERATURE (ECT) SENSOR INSPECTION [MZR-CD 2.2]
id0140f2445600
Resistance Inspection
1. Remove the ECT sensor. (See ENGINE COOLANT TEMPERATURE (ECT) SENSOR REMOVAL/INSTALLATION [MZR-CD 2.2].)
2. Place the ECT sensor in water with a thermometer, and heat the water gradually.
3. Measure the resistance between the ECT sensor terminals using an ohmmeter.
Specification
Water temperature (°C {°F}) |
Resistance (kilohm) |
---|---|
20 {68}
|
2.21—2.69
|
80 {176}
|
0.29—0.34
|