ON-BOARD DIAGNOSTIC FUNCTION
id070200100300
Malfunction detection function
Fail-safe function
Fail-safe Function Table
Part where malfunction is determined |
Malfunction determined when IG SW at ON |
Malfunction already exists when IG SW turned to ON |
---|---|---|
Cabin temperature sensor
|
Cabin temperature sensor input value is fixed at the value right before the malfunction.
|
Cabin temperature sensor input value is fixed at 25 °C {77 °F}.
|
Evaporator temperature sensor
|
Evaporator temperature sensor input value is fixed at 0 °C {32 °F}.
|
←
|
Solar radiation sensor
|
Solar radiation sensor value is fixed at the value right before the malfunction.
|
Solar radiation sensor value is fixed at 0 W/m2.
|
Air mix actuator
(potentiometer)
|
Air mix actuator drive signal is stopped right when the malfunction is determined.
However, it is fixed at MAX COLD when the manually set temperature is at 15 and fixed at MAX HOT when the manually set temperature is at 29.
|
Control based on ambient temperature. (See Graph 1.)
However, it is fixed at MAX COLD when the manually set temperature is at 15 and fixed at MAX HOT when the manually set temperature is at 29.
|
Airflow mode actuator
(potentiometer)
|
Airflow mode actuator drive signal is stopped right when the malfunction is determined.
• However, change the operation to VENT or DEF when the manual operation selected to VENT or DEF.
|
Control based on ambient temperature. (See Graph 2.)
• However, change the operation to VENT or DEF when the manual operation selected to VENT or DEF.
|
Air mix actuator
(motor lock)
|
Air mix actuator drive signal is stopped right when the malfunction is determined.
|
Air mix actuator drive signal is output normally. After this, a drive signal is stopped when the malfunction is determined.
|
Airflow mode actuator
(motor lock)
|
Airflow mode actuator drive signal is stopped right when the malfunction is determined.
|
Airflow mode actuator drive signal is output normally. After this, a drive signal is stopped when the malfunction is determined.
|
acxuun00000222
|
Sensor Signal Delay Function
acxuun00000223
|
Memory Function
Display Function
DTC table (climate control system)
DTC |
Malfunction location |
Detected condition |
Memory function |
---|---|---|---|
B1081:71
|
Left side air mix actuator
|
Stuck
|
X
|
B1082:71
|
Right side air mix actuator
|
Stuck
|
X
|
B1086:71
|
Airflow mode actuator
|
Stuck
|
X
|
B1A61:11
|
Cabin temperature sensor
|
Circuit short to ground
|
X
|
B1A61:13
|
Circuit open
|
X
|
|
B1A63:12
|
Solar radiation sensor (RH)
|
Circuit shot to power supply
|
—
|
B1A63:13
|
Circuit open
|
—
|
|
B1A64:12
|
Solar radiation sensor (LH)
|
Circuit shot to power supply
|
—
|
B1A64:13
|
Circuit open
|
—
|
|
B1B71:11
|
Evaporator temperature sensor
|
Circuit short to ground
|
X
|
B1B71:13
|
Circuit open
|
X
|
|
B1C1A:11
|
Left side air mix actuator (potentiometer)
|
Circuit short to ground
|
X
|
B1C1A:13
|
Circuit open
|
X
|
|
B1C1B:11
|
Right side air mix actuator (potentiometer)
|
Circuit short to ground
|
X
|
B1C1B:13
|
Circuit open
|
X
|
|
B1C1C:11
|
Airflow mode actuator (potentiometer)
|
Circuit short to ground
|
X
|
B1C1C:13
|
Circuit open
|
X
|
|
U0010:88
|
CAN communication system
|
Bus off
|
X
|
U0155:00
|
Lost communication with Instrument cluster
|
No sub type information
|
X
|
U0184:00
|
Lost communication with audio unit/car-navigation unit
|
No sub type information
|
—
|
U0423:68
|
Invalid data received from instrument cluster
|
Event information
|
X
|
DTC table (water heater system)
DTC |
Malfunction location |
Detected condition |
Memory function |
---|---|---|---|
B1D24:11
|
Glow plug
|
Circuit short to ground
|
X
|
B1D24:15
|
Circuit short to power supply or open
|
X
|
|
B1D25:11
|
Fuel pump (water heater system)
|
Circuit short to ground
|
X
|
B1D25:15
|
Circuit short to power supply or open
|
X
|
|
B1D26:11
|
Blower fan
|
Circuit short to ground
|
X
|
B1D26:15
|
Circuit short to power supply or open
|
X
|
|
B1D29:93
|
No start, even after restart attempt
|
No operation
|
X
|
B1D30:93
|
No start in test mode
|
No operation
|
X
|
B1D31:94
|
Flame detected prior to normal operation
|
Unexpected operation
|
X
|
B1D32:92
|
Multiple flame interruption during heating cycle
|
Performance or incorrect operation
|
X
|
B1D34:68
|
Heater in lock out mode
|
Event information
|
X
|
U0001:88
|
HS-CAN communication bus
|
Bus off
|
X
|
U0100:00
|
Lost communication with PCM
|
No sub type information
|
X
|
U0140:00
|
Lost communication with BCM
|
No sub type information
|
X
|
U0155:00
|
Lost communication with instrument cluster
|
No sub type information
|
X
|
U3000:49
|
Control module
|
Internal electronic failure
|
X
|
U3003:16
|
Power supply circuit (battery voltage)
|
Circuit voltage below threshold
|
X
|
U3003:17
|
Circuit voltage above threshold
|
X
|
PID/data Monitor Function
PID/data monitor table (climate control system)
PID name (definition) |
Input part |
Unit/Condition |
---|---|---|
CABIN_TEMP
|
Cabin temperature sensor
|
°C
|
EVAP_TEMP
|
Evaporator temperature sensor
|
°C
|
SOLAR_SSR_L
|
Solar radiation sensor (LH)
|
W
|
SOLAR_SSR_R
|
Solar radiation sensor (RH)
|
W
|
PID/data monitor table (water heater system)
PID name (definition) |
Input signal |
Unit/Condition |
---|---|---|
ECT
|
Engine coolant temperature
|
°C
|
EX_TEMP
|
Ambient temperature
|
°C
|
GLOW_PLUG
|
Glow plug duty cycle
|
%
|
HEATER_FAN
|
Heater fan
|
V
|
PRIM_TIME
|
Priming time
|
s
|
RPM
|
Engine revolutions per minute
|
RPM
|
START_CNT
|
Start counter
|
-
|
VOLT_LOW
|
Low voltage threshold
|
V
|
VOLT_OP
|
Operating voltage
|
V
|
VPWR
|
Module supply voltage
|
V
|
WATER_TEMP
|
Water temperature
|
°C
|
Active Command Modes Function
Active command modes table
Command name |
Output part |
Operation |
Operating condition |
---|---|---|---|
BLOWER
|
Blower motor
|
On/Off
|
Ignition is switched to ON
|
DISPLAY
|
Information display
|
||
MODE_ACT
|
Airflow mode actuator
|
||
MIX_ACT
|
Air mix actuator
|
||
REC/FRESH
|
REC/FRESH switch
|
A/C Operation Check Mode
Mazda Modular Diagnostic System (M-MDS) display |
Target part |
Operation condition |
---|---|---|
Illumination of All Indicator Lights
|
Climate control unit
|
All A/C indicator lights illuminated
|
Blower Motor Speed
|
Blower motor
|
![]() |
Air Mix Actuator
|
Air mix door
|
![]() |
Air Flow Mode Actuator
|
Airflow mode door
|
![]() |
Air Intake Actuator / Air Conditioning Compressor
|
Air intake door
A/C compressor
|
FRESH Û REC