SIDE HOUSING (FRONT, INTERMEDIATE, REAR) INSPECTION


id011000131400

1.   Inspect the intermediate housing for clogging in the intake and exhaust port.

Note
•  Carefully inspect the anti-wet port of the intermediate housing since it is an essential port.
chu0110e001
•  If there is any malfunction, replace the corresponding side housing.

2.  Inspect the side housing for distortion in four positions as shown in the figure using a straight edge and a feeler gauge.

bhj0110e026

•  If the distortion exceeds the maximum, replace the corresponding side housing.
Maximum distortion
0.04 mm {0.0016 in}

3.   Inspect the following three items related to wear in the areas where the rotor contacts the side housing using a dial gauge.

•  If any one of the items exceeds the maximum, replace the corresponding side housing.
(1)  Vertical wear
chu0110e002
Maximum wear
0.10 mm {0.0039 in}
(2)  Convex oval
chu0110e003
Maximum wear
Oil seal inner path (A): 0.01 mm {0.0004 in}
Oil seal outer path (B): 0.10 mm {0.0039 in}
(3)  Oil seal stepped path wear
chu0110e004
Maximum wear
0.02 mm {0.0008 in}