ECCENTRIC SHAFT BYPASS VALVE


id011000134500

Warning
•  Engine oil temperature will increase during the inspection and become very dangerous. Be careful not to burn yourself during the inspection.

1.  Put the eccentric shaft bypass valve in a container filled with engine oil.

chu0110e057

2.  Heat the container and verify that the projection protrudes more than the minimum specification when the engine oil temperature is 60 °C {140 °F}.

•  If it is less than the minimum specification, replace the eccentric shaft bypass valve.
Minimum projection
6 mm {0.24 in}