MAIN BEARING OIL CLEARANCE INSPECTION
id011000135100
1. Using a micrometer, measure the outer diameters of the inside main journal.
chu0110e022
|
2. Using a cylinder bore gauge, measure the inner diameter of the stationary gear main bearing.
bhj0110e056
|
3. Calculate the main bearing oil clearance from the main journal outer diameter and the main bearing inner diameter.
chu0110e023
|