A/C CUT-OFF CONTROL OPERATION [13B-MSP]


id0140g1103700


Operation

•  The A/C cut-off control includes the following: A/C cut-off at wide throttle valve opening angle and A/C cut-off at standing start acceleration.

A/C Cut-off at Wide Throttle Valve Opening Angle


Operation condition

•  When the throttle valve opening angle exceeds upper, A/C cut-off is activated for approx. 5 s to improve acceleration performance.
•  When the throttle valve opening angle is lower or less, A/C cut-off ends.
•  When A/C cut-off at wide throttle valve opening angle ends within approx. 5 s and the throttle valve opening angle exceeds upper again, A/C cut-off is inhibited to prevent deterioration of the A/C function.
ar8wzn00000571


A/C Cut-off at Standing Start Acceleration

•  When accelerated from a standing start, A/C cut-off is activated.

A/C Cut-off at High ECT

•  When the ECT exceeds 110 °C {230°F} during the A/C operation, the A/C relay alternately turns on and off approx. every 10 s to protect the engine and to prevent deterioration of the A/C function.
ar8wzn00000572