DTC 02


id070200802100

DTC 02

Solar radiation sensor system inspection

POSSIBLE CAUSE
•  Solar radiation sensor malfunction
•  Open circuit in wiring harness between solar radiation sensor connector terminal B and A/C amplifier connector terminal 2I
•  Open circuit in wiring harness between solar radiation sensor connector terminal A and A/C amplifier connector terminal 2P
•  Short to ground in wiring harness between solar radiation sensor connector terminal B and A/C amplifier connector terminal 2I
•  Connector or terminal malfunction

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
INSPECT SOLAR RADIATION SENSOR
•  Inspect the solar radiation sensor.
•  Is it normal?
Yes
Go to the next step.
No
Replace the solar radiation sensor.
2
INSPECT SOLAR RADIATION SENSOR CIRCUIT FOR OPEN CIRCUIT
•  Disconnect the A/C amplifier connector (16-pin) and the solar radiation sensor connector.
•  Is there continuity between the following terminals of the A/C amplifier connector (16-pin) and the solar radiation sensor connector?
―  2I—B
―  2P—A
Yes
Go to the next step.
No
Repair the wiring harness.
3
INSPECT SOLAR RADIATION SENSOR CIRCUIT FOR SHORT TO GROUND
•  Is there a short circuit to ground in the wiring harness between A/C amplifier connector (16-pin) terminal 2I and solar radiation sensor connector terminal B?
Yes
Repair the wiring harness.
No
Inspect the connection at the A/C amplifier connector (16-pin).