DTC 59
id070200803800
DTC 59 |
Airflow mode actuator (motor lock) system inspection |
---|---|
POSSIBLE CAUSE
|
• Airflow mode actuator malfunction
• A/C unit (airflow mode link and airflow mode crank) malfunction
• Connector or terminal malfunction
• Open circuit in wiring harness between A/C amplifier connector terminals 1W and 1X
• Short to ground in wiring harness between A/C amplifier connector terminals 1W and 1X
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Disconnect the airflow mode actuator connector.
• Connect battery positive voltage to airflow mode actuator terminal F (or terminal G) and ground to terminal G (or terminal F).
• Does the airflow mode actuator operate?
|
Yes
|
Connect the connector, then go to Step 3.
|
No
|
Go to the next step.
|
||
2
|
• Remove the airflow mode actuator.
• Operate the airflow mode main link manually.
• Does the airflow mode main link operate smoothly?
|
Yes
|
Replace the airflow mode actuator.
|
No
|
Replace the airflow mode main link, airflow mode sub link, and the airflow mode crank.
|
||
3
|
• Disconnect the A/C amplifier connector (24-pin).
• Connect battery positive voltage to A/C amplifier connector (24-pin) terminal 1W (or terminal 1X) and ground to terminal 1X (or terminal 1W).
• Does the airflow mode actuator operate?
|
Yes
|
Inspect the connection at the A/C amplifier connector (24-pin).
|
No
|
Repair the wiring harness.
|
||
![]() |