DTC 59


id070200803800

DTC 59

Airflow mode actuator (motor lock) system inspection

POSSIBLE CAUSE
•  Airflow mode actuator malfunction
•  A/C unit (airflow mode link and airflow mode crank) malfunction
•  Connector or terminal malfunction
•  Open circuit in wiring harness between A/C amplifier connector terminals 1W and 1X
•  Short to ground in wiring harness between A/C amplifier connector terminals 1W and 1X

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
•  Disconnect the airflow mode actuator connector.
•  Connect battery positive voltage to airflow mode actuator terminal F (or terminal G) and ground to terminal G (or terminal F).
•  Does the airflow mode actuator operate?
Yes
Connect the connector, then go to Step 3.
No
Go to the next step.
2
•  Remove the airflow mode actuator.
•  Operate the airflow mode main link manually.
•  Does the airflow mode main link operate smoothly?
Yes
Replace the airflow mode actuator.
No
Replace the airflow mode main link, airflow mode sub link, and the airflow mode crank.
3
•  Disconnect the A/C amplifier connector (24-pin).
•  Connect battery positive voltage to A/C amplifier connector (24-pin) terminal 1W (or terminal 1X) and ground to terminal 1X (or terminal 1W).
•  Does the airflow mode actuator operate?
Yes
Inspect the connection at the A/C amplifier connector (24-pin).
No
Repair the wiring harness.