NO.2 AMOUNT OF AIR BLOWN FROM VENTS DOES NOT CHANGE [FULL-AUTO AIR CONDITIONER]
id0703c1800500
2
|
Amount of air blown from vents does not change.
|
DESCRIPTION
|
• Malfunction in blower system.
|
POSSIBLE CAUSE
|
• Blower motor malfunction (Steps 3, 4, 12)
• Blower unit malfunction (Steps 5—9)
• Power transistor system malfunction (Steps 10, 11, 13, 14)
• Climate control unit malfunction (Step 15)
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT A/C 7.5 A FUSE
• Inspect A/C 7.5 A fuse.
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
Replace fuse, then go to Step 15. If fuse burns out immediately, go to the next step.
|
||
2
|
CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER UNIT OR ELSEWHERE
• Turn ignition switch to ON position.
• Recirculate air inside vehicle.
• Does fan in blower unit rotate smoothly?
|
Yes
|
Go to Step 4.
|
No
|
Go to the next step.
|
||
3
|
INSPECT BLOWER UNIT INTAKE VENT
• Is intake vent of blower unit clogged?
|
Yes
|
Remove obstruction, then go to Step 15.
|
No
|
Inspect if there are any obstruction in passage between blower unit to A/C unit, then go to Step 15.
|
||
4*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER RELAY SYSTEM OR POWER TRANSISTOR SYSTEM
• Turn ignition switch to ON position.
• Test voltage at the following terminal of blower motor.
• Is voltage approx. 12 V?
|
Yes
|
Go to Step 8.
|
No
|
Go to the next step.
|
||
5*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN FUSE BLOCK AND BLOWER RELAY) OR ELSEWHERE
• Test voltage at the following terminal of blower relay.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between blower relay and HEATER 40 A fuse, then go to Step 15.
|
||
6*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND GROND) OR ELSEWHERE
• Test voltage at the following terminal of blower relay.
• Is voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between blower relay and ground, then go to Step 15.
|
||
7*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER RELAY AND BLOWER MOTOR) OR BLOWER RELAY
• Test voltage at the following terminal of blower relay.
• Is voltage approx. 12 V?
|
Yes
|
Repair wiring harness between blower relay and blower motor, then go to Step 15.
|
No
|
Replace blower relay, then go to Step 15.
|
||
8*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN BLOWER MOTOR OR ELSEWHERE
• Test voltage at the following terminal of blower motor.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Inspect blower motor, then go to Step 15.
|
||
9*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN BLOWER MOTOR AND POWER TRANSISTOR) OR ELSEWHERE
• Test voltage at the following terminal of power transistor.
• Is voltage approx. 12 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between blower motor and power transistor, then go to Step 15.
|
||
10*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN POWER TRANSISTOR AND GROUND) OR ELSEWHERE
• Test voltage at the following terminal of power transistor.
• Is voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between power transistor and ground, then go to Step 15.
|
||
11
|
INSPECT BLOWER UNIT
• Inspect fan in blower unit.
• Is voltage approx. 0 V?
|
Yes
|
Go to the next step.
|
No
|
Remove obstruction, repair or replace fan and blower unit case, then go to Step 15.
|
||
12*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN POWER TRANSISTOR OR ELSEWHERE
• Disconnect power transistor connector.
• Test voltage at the following terminal of power transistor.
• Is voltage approx. 10 V?
|
Yes
|
Replace power transistor, then go to Step 15.
|
No
|
Go to the next step.
|
||
13*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY BETWEEN POWER TRANSISTOR AND A/C AMPLIFIER) OR ELSEWHERE
• Turn ignition switch to LOCK position.
• Disconnect A/C amplifier connector.
• Inspect for continuity at the following terminals between power transistor and A/C amplifier.
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Repair wiring harness between power transistor and A/C amplifier, then go to Step 15.
|
||
14*
|
CHECK TO SEE WHETHER MALFUNCTION IS IN A/C AMPLIFIER OR WIRING HARNESS (SHORT TO GROUND BETWEEN POWER TRANSISTOR AND A/C AMPLIFIER) OR ELSEWHERE
• Inspect for continuity at the following terminal between power transistor and ground.
• Is there continuity?
|
Yes
|
Repair wiring harness between power transistor and ground, then go to the next step.
|
No
|
Replace A/C amplifier, then go to the next step.
|
||
15
|
VERIFY THAT MALFUNCTION SYMPTOM OCCURS AFTER REPAIR
• Is air discharged from vent?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|